LSI LSISAS1064 User Manual Download Page 1

®

PCI-X to 3.0 Gbit/s
Serial Attached SCSI 
(SAS) Host Adapters

 DB15-000333-02

USER’S

GUIDE

J u n e   2 0 0 6

Version 2.1

Model Numbers: 

LSISAS3041X, LSISAS3041XL
LSISAS3442X, LSISAS3442XL
LSISAS3080X, LSISAS3080XL
LSISAS3800X
LSISAS3801X, LSISAS3801XL

Summary of Contents for LSISAS1064

Page 1: ...Serial Attached SCSI SAS Host Adapters DB15 000333 02 USER S GUIDE J u n e 2 0 0 6 Version 2 1 Model Numbers LSISAS3041X LSISAS3041XL LSISAS3442X LSISAS3442XL LSISAS3080X LSISAS3080XL LSISAS3800X LSIS...

Page 2: ...connected Consult the dealer or an experienced radio TV technician for help Shielded cables for SCSI connection external to the cabinet are used in the compliance testing of this Product LSI Logic is...

Page 3: ...officer is prohibited LSI Logic Corporation reserves the right to make changes to any products herein at any time without notice LSI Logic does not assume any responsibility or liability arising out o...

Page 4: ...iv Version 2 1 Copyright 2005 2006 by LSI Logic Corporation All rights reserved...

Page 5: ...sumes that you have some familiarity with Serial Attached SCSI SAS devices and PCI PCI X devices This document benefits people installing and using the host adapter Organization This document has the...

Page 6: ...ement User s Guide Document No DB15 000186 xx Integrated RAID User s Guide Document No DB15 000292 xx LSI World Wide Web Home Page www lsilogic com ANSI 11 West 42nd Street New York NY 10036 212 642 4...

Page 7: ...include the LSISAS3801X and LSISAS3801XL The LSI PCI Express boards are now contained in another doc ument DB15 000363 00 DB15 000333 01 Version 2 0 March 2006 Updated document to include the PCI Expr...

Page 8: ...viii Preface Version 2 1 Copyright 2005 2006 by LSI Logic Corporation All rights reserved...

Page 9: ...3 1 Characteristics of the PCI X to 3 0 Gbit s SAS Host Adapters 3 1 3 1 1 LSISAS3041X and LSISAS3041XL Host Adapters Characteristics 3 2 3 1 2 LSISAS3442X and LSISAS3442XL Host Adapters Characterist...

Page 10: ...x Contents Version 2 1 Copyright 2005 2006 by LSI Logic Corporation All rights reserved...

Page 11: ...ost Adapter in a PCI X Slot 2 3 2 2 Installing a PCI X to 3 0 Gbit s SAS x8 Host Adapter in a PCI X Slot 2 4 3 1 LSISAS3041X and LSISAS3041XL Board Layout 3 3 3 2 LSISAS3442X and LSISAS3442XL Board La...

Page 12: ...xii Contents Version 2 1 Copyright 2005 2006 by LSI Logic Corporation All rights reserved...

Page 13: ...n 2 1 Copyright 2005 2006 by LSI Logic Corporation All rights reserved Tables 1 1 PCI X to 3 0 Gbit s Host Adapters and Controllers 1 2 1 2 SAS Bandwidths 1 3 1 3 Software Support 1 5 3 1 Maximum Powe...

Page 14: ...xiv Contents Version 2 1 Copyright 2005 2006 by LSI Logic Corporation All rights reserved...

Page 15: ...o wait state bus master with data bursts up to 1064 Mbytes s on a 64 bit PCI X 133 MHz bus These LSI host adapters contain Flash ROM for storing the BIOS and firmware and NVSRAM for storing nonvolatil...

Page 16: ...he design of these host adapters make it easy to add SAS interfaces to any computer workstation or server with a PCI PCI X bus Table 1 1 shows the LSI SAS controllers and their associated host adapter...

Page 17: ...ace Transfers data using SCSI information units Provides two LEDs for each phy to indicate link activity and faults for the LSISAS3041X LSISAS3041XL LSISAS3442X LSISAS3442XL LSISAS3800X LSISAS3801X an...

Page 18: ...I Local Bus Specification revision 2 0 Complies with the PCI Bus Power Management Interface Specification revision 1 2 Complies with the PC2001 Specification Provides unequalled performance through th...

Page 19: ...ertification effort 1 4 Software The LSI PCI X to 3 0 Gbit s SAS host adapters support all major operating systems as shown in Table 1 3 These host adapters use the Fusion MPT architecture for all maj...

Page 20: ...1 6 Introduction Version 2 1 Copyright 2005 2006 by LSI Logic Corporation All rights reserved...

Page 21: ...o install your PCI X to 3 0 Gbit s SAS host adapter if you are comfortable with the installation procedure Section 2 2 provides detailed installation instructions Step 1 Unpack the host adapter and in...

Page 22: ...p 4 Insert the host adapter in an available PCI PCI X slot Locate an empty PCI PCI X slot Remove the blank bracket panel on the back of the computer that is aligned with the PCI PCI X slot you have se...

Page 23: ...ystem s cover reconnect the power cord s and any network cables Turn power on to the system The PCI X to 3 0 Gbit s SAS host adapter hardware installation is complete Figure 2 1 Installing a PCI X to...

Page 24: ...ing a PCI X to 3 0 Gbit s SAS x8 Host Adapter in a PCI X Slot Note The HBA shape size and locations of components on your x8 HBA and its bracket may vary from this illustration 32 bit Slots 64 bit Slo...

Page 25: ...roller connects up to eight SAS SATA devices to a computer system through the PCI PCI X interface In both cases the use of LSI expanders provides substantially more connectivity The LSISAS1064 and the...

Page 26: ...reen to indicate an activity condition on any of the four phys There are four LEDs that turn yellow to indicate a fault condition on any of the four phys See Figure 3 1 for LED locations There is one...

Page 27: ...t angle connectors 3 1 1 3 Physical Characteristics The LSISAS3041X and LSISAS3041XL boards are 6 6 inches x 2 536 inches PCI PCI X connection is made through the edge connector J1 The component heigh...

Page 28: ...indicate the LSISAS1068 heartbeat or it turns yellow when the LSISAS1068 firmware detects a fault condition 3 1 2 2 Connectors This section provides a description of the three different connectors on...

Page 29: ...J1 PCI PCI X 64 bit 3 3 V type board edge connector J2 SFF 8470 SAS external right angle connector J5 SFF 8484 SAS internal right angle connector with four sideband lines 3 1 2 3 Physical Characterist...

Page 30: ...S3080XL host adapters See Figure 3 3 for connector locations PCI PCI X Connector J1 The PCI PCI X interface operates as a 32 bit or 64 bit DMA bus master The connection is made through the edge connec...

Page 31: ...ternal right angle connectors with four sideband lines 3 1 3 3 Physical Characteristics The LSISAS3080X and LSISAS3080XL are 6 6 inches x 2 536 inches PCI PCI X connection is made through the edge con...

Page 32: ...ight pipe is bi color It flashes green to indicate the LSISAS1068 heartbeat or it turns yellow when the LSISAS1068 firmware detects a fault condition 3 1 4 2 Connectors This section provides a descrip...

Page 33: ...connectors J8 4 pin right angle 0 1 inch pitch pin header for driving external activity LED 3 1 4 3 Physical Characteristics The LSISAS3800X board is 6 6 inches x 3 8 inches PCI PCI X connection is m...

Page 34: ...any phy The other light pipe is bi color It flashes green to indicate the LSISAS1068 heartbeat or it turns yellow when the LSISAS1068 firmware detects a fault condition 3 1 5 2 Connectors This sectio...

Page 35: ...connectors J6 4 pin right angle 0 1 inch pitch pin header for driving external activity LED 3 1 5 3 Physical Characteristics The LSISAS3801X and LSISAS3801XL boards are 6 6 inches x 2 536 inches PCI...

Page 36: ...cteristics Table 3 1 lists the maximum power requirements for the PCI X to 3 0 Gbit s SAS host adapters under normal operation The PCI PCI X PRSNT1 and PRSNT2 pins are set to indicate 7 5 W maximum co...

Page 37: ...apters Temperature range 40 C to 105 C dry bulb Relative humidity range 5 to 90 non condensing 3 2 3 Safety Characteristics All PCI X to 3 0 Gbit s SAS host adapters meet or exceed the requirements of...

Page 38: ...3 14 Host Adapter Characteristics Version 2 1 Copyright 2005 2006 by LSI Logic Corporation All rights reserved...

Page 39: ...nt Please copy the following page add your comments and fax it to us at the number shown If appropriate please also fax copies of any marked up pages from this document Important Please include your n...

Page 40: ...please specify the error and page number If appropriate please fax a marked up copy of the page s Please complete the information below so that we may contact you directly for clarification or additi...

Reviews: