6-52
Electrical Specifications
Figure 6.31 Slow Memory (
≤
=
128 Kbytes) Read Cycle
Table 6.36
Slow Memory (
≤
=
128 Kbytes) Read Cycle
Symbol
Parameter
Min
Max
Unit
t
11
Address setup to MAS/ HIGH
25
–
ns
t
12
Address hold from MAS/ HIGH
15
–
ns
t
13
MAS/ pulse width
25
–
ns
t
14
MCE/ LOW to data clocked in
150
–
ns
t
15
Address valid to data clocked in
205
–
ns
t
16
MOE/ LOW to data clocked in
100
–
ns
t
17
Data hold from address, MOE/, MCE/ change
0
–
ns
t
18
Address out from MOE/, MCE/ HIGH
50
–
ns
t
19
Data setup to CLK HIGH
5
–
ns
t
14
t
18
t
19
t
17
t
11
t
12
t
13
t
15
t
16
CLK
MAS1/
(Driven by LSI53C895A)
MAS0/
(Driven by LSI53C895A)
MCE/
(Driven by LSI53C895A)
MOE/
(Driven by LSI53C895A)
MWE/
(Driven by LSI53C895A)
MAD
(Address driven by LSI53C895A;
Data driven by Memory)
Higher
Address
Middle
Address
Lower
Address
Valid Read Data