Alpha-Log
–
User manual
LSI LASTEM SRL
INSTUM_03388
Page 103 / 116
Alpha-Log configuration templates
Type 1 configuration: Alpha-Log + ALIEM
Alpha-Log
Sensor
Quantity
DQA230.1
Rain
DMA672.1
TempUR
DLE041
Ground temperature
DQA340
Water content
-
Pressure (internal)
-
Temperature (internal)
ALIEM
Sensor
Quantity
DNA121
Wind Speed+Dir
DPA154
Global Rad.
DQC102
Evaporation
DLE124
Contact temperature
DQC001.15
Water level
Sensor
code
Measure (UM)
Acq. rate
hh:mm:ss
Elaborations
(rata hh:mm
–
tipo)
Alpha-Log
input
DQA230
RAIN (mm)
00:01:00
00:10
–
Tot
01:00
–
Tot
24:00
–
Tot
Last 10 min
–
Mobile tot
Last 60 min
–
Mobile tot
Pulse/Freq1
DMA672.3
Temperature (°C)
00:01:00
00:10 - Min, Med, Max, DevStd
01:00 - Min, Med, Max, DevStd
24:00 - Min, Med, Max, DevStd
TTL Serial
RelHumidity (%)
00:01:00
00:10 - Min, Med, Max, DevStd
01:00 - Min, Med, Max, DevStd
DLE041
Temperature (°C)
00:01:00
00:10 - Min, Med, Max, DevStd
01:00 - Min, Med, Max, DevStd
Last 60 min
–
Mobile med
Pt100
DQA340
VolMoisture (%)
00:01:00
00:10 - Min, Med, Max, DevStd
01:00 - Min, Med, Max, DevStd
Analog In
SOILTemp (°C)
00:01:00
00:10 - Min, Med, Max, DevStd
01:00 - Min, Med, Max, DevStd
Last 60 min
–
Mobile med
-
AtmPres (hPa)
00:01:00
00:10 - Min, Med, Max, DevStd
01:00 - Min, Med, Max, DevStd
On board
-
INSideTemp (°C)
00:01:00
00:10 - Min, Med, Max, DevStd
01:00 - Min, Med, Max, DevStd
On board