Summary of Contents for MDRJ

Page 1: ... Document Number MDR T0U A1 doc Version 1 1 LSC Lighting Systems Aust Pty Ltd ABN 21 090 801 675 Building 3 66 74 Micro Circuit Dandenong South Victoria 3175 Australia Tel 61 3 9702 8000 Fax 61 3 9702 8466 email info lsclighting com web www lsclighting com ...

Page 2: ......

Page 3: ...DMX when you need it The range encompasses a 5 way and 10 way 19 Rack Mount configuration as well as a 5 way portable version that can be truss mounted as well as used free standing The two 5 way versions allow the option of adding both RDM and Wireless DMX modules whereas the 10 way only allows the addition of RDM as an option Additionally an installation version comprising all RJ45 style connect...

Page 4: ...russ or pipe The second method is a factory supplied option consisting of a metal bracket and fixing bolts that allows the splitter to have a coupler or hook clamp attached For either method it is recommended to feed a suitably rated safety wire chain through the end cavities of the splitter and fasten around the pipe truss handrail Fuseholder 0 5 Amp rated fuse Recessed cavity for storing aerial ...

Page 5: ... splitter Note All outputs are individually isolated from each other as well as the input Isolation is for both data and common connections and provides a galvanic barrier to 1500 Volts Outputs are EMI filtered and current limited to protect against short circuits RDM Operation The RDM module when fitted allows RDM based devices to communicate with each other in bi directional mode interleaved wit...

Page 6: ...e 2 For Wireless Solutions W DMX models press and release the FUNCTION button to synchronise the receiver to the transmitter device This process may take up to 10 seconds to synchronise Once synchronised the STATUS indicator will illuminate 3 To unlink the receiver from the transmitter press and hold the FUNCTION button until the Status indicator goes off The receiver is now not linked to the tran...

Page 7: ...etres in length When several DMX streams are required to feed different locations DMX512 splitters must be used These provide multiple isolated DMX512 output streams of the same input stream Note Do not use unscreened microphone or low speed data cables for DMX This can cause problems in the DMX network Make sure the cable conforms to the EIA485 cable requirements by providing the following specif...

Page 8: ...lots each item requires This information could then be used to auto patch the entire rig The user settings of all the devices could be saved as part of the show file so that when the show is re loaded into the console the system could ensure that all devices are still connected and working then check that the Pan invert settings and custom dimmer curves on certain devices have not changed In the c...

Page 9: ... Power Supply On LED Yes Yes Yes Yes 19 Rack Mount Chassis Yes Yes No Yes Conforms to CE regulations Yes Yes Yes Yes Disclaimer LSC Lighting Systems Aust Pty Ltd supplies the enclosed information in good faith LSC Lighting Systems Aust Pty Ltd makes no representations or warranties with respect to the contents or use of this manual and specifically disclaims any implied warranties of merchantabili...