Basic Functions
90
Output voltage adjustment
7.5.5
Group
Code
Parameter Name
Setting
Range
Default
Unit
Function group 1
F39
[Output voltage
adjustment]
-
40 - 110
100
%
This function is used to adjust the output voltage of the inverter. This is useful when you
use a motor that has a rated voltage lower than the input voltage.
Manual torque boost
7.5.6
Group
Code
Parameter Name
Setting
Range
Default
Unit
Function group 1
F27
[Torque Boost select]
0
0 - 1
0
F28
[Torque boost in forward
direction]
-
0 - 15
4
%
F29
[Torque boost in reverse
direction]
Set F27 to 0 {Manual torque boost}.
The values of [Torque boost in forward/reverse direction] are set separately in F28 and
F29.