background image

STARVERT - iG5A

 

 

MAINTENANCE GUIDE

 

- This guide contains safety information and basic troubleshooting and  

maintenance guidance. For more detailed information, refer to the user manual 
included with the product or contact your supplier. 

- For your safety, carefully read the Maintenance Guide before you install and 

use the product. 

Safety information 

 

  Read and follow all safety instructions in this guide to understand the safe operating 

conditions for the equipment and to avoid property damage and personal injury. 

  For your safety, Warning and Caution information is provided below. 

Warning

 

Caution

 

Indicates an imminently hazardous situation which, if not  
avoided, may result in severe injury or death. 

Indicates a potentially hazardous situation which, if not 
avoided, may result in injury or damage to property. 

 

Do not open the inverter covers while it is energized or operating.

 

Doing so may cause the inverter to malfunction or result in electric shock. 

Do not allow objects, such as metal filings or other debris inside the inverter. 

Doing so may cause the inverter to malfunction or result in a fire. 

Warning 

 

Ensure that cables are correctly specified for the inverter’s rated voltage, cable entry,  
and terminal arrangement. Ensure that all wiring connections  are installed correctly.

 

Incorrect  cable specifications and connections may cause the inverter to malfunction or result  
in a fire. 

Apply the correctly  rated torque when tightening  terminal screws.

 

Loose screws or over tightened screws may result in an electric shock or a fire. 

Do not install the inverter near flammable objects.

 

Doing so may cause a fire. 

Ensure that the inverter location or installation  method is not affected by vibration.

 

Vibration 

may affect the inverter’s operation and result in an electric shock or fire. 

Ensure that the inverter is not serviced or repaired by unauthorized  persons. 

Unauthorized work may result in an electric shock or a fire and void the warranty. 

Ensure the inverter load does not exceed the product’s rated load and that the inverter is 
installed in accordance with the environmental conditions specified in the User’s  
Manual.    

Exceeding the rated load or incorrectly installing the inverter may cause the inverter to 
malfunction, overheat, or result in an electric shock or a fire. 

Caution 

- 1 -  

- 2 -  

Summary of Contents for Starvert-iG5A

Page 1: ...use the inverter to malfunction or result in a fire Warning Ensure that cables are correctly specified for the inverter s rated voltage cable entry and terminal arrangement Ensure that all wiring connections are installed correctly Incorrect cable specifications and connections may cause the inverter to malfunction or result in a fire Apply the correctly rated torque when tightening terminal screw...

Page 2: ... least 10 minutes after the inverter is turned off Safety information for wiring 1 Do not allow objects such as metal filings or cable off cuts inside the inverter Doing so may damage the inverter or cause inverter malfunction 2 Apply the correctly rated torque when tightening screws If screws are loose or over tightened the inverter may malfunction or cause a short circuit 3 If the forward comman...

Page 3: ...tly rated MCCBs Contact the manufacturer for further information M C Magnetic contactor Avoid starting and stopping the inverter unnecessarily It may impact the lifespan and reliability of the product and cause switching noise Select correctly rated M Cs Contact the manufacturer for further information Reactor AC and DC reactors Protects the inverter when a high load is connected suppresses high f...

Page 4: ...r 10 sec this feature has inverse time characteristics ETH Electronic thermal Stops the inverter operation to protect the motor when a current exceeding the motor rated current is supplied for a specific period of time Default value 150 of the motor s rated current detected for 60 sec This feature has inverse time characteristics The inverter output current exceeds the motor s rated current Voltag...

Page 5: ...tput Input voltage is too high Increase the acceleration time Use the braking unit Ensure the input voltage is at the specified value Low voltage Input voltage too low A load greater than the power capacity is connected to the inverter e g a welder direct motor connection etc The magnetic contactor on the input side has a connection fault Ensure the input voltage is at the specified value Increase...

Page 6: ...eck the operation and frequency commands Reduce the load or increase the inverter rating Adjust the parameter Type Cause Remedy The motor vibrates severely does not rotate normally and stalls There are large load fluctuations The input voltage is not stable The torque boost value is too high Adjust the load to the rated value Ensure the input voltage is correct Adjust the torque boost value The mo...

Page 7: ... and s com U S A HIGH END SP Tel 55 19 9788 4426 Email winderson heautomacao com br BRAZIL VMC Barcelona Tel 34 935 747 017 Email xgarcia vmc es SPAIN HEIGL Rosbach Tel 49 6003 3457 Email t heigl heigl antriebe de GERMANY PNEUMO Saint Petersburg Tel 49 6003 3457 Email t heigl heigl antriebe de RUSSIA ANT Istanbul Tel 90 216 499 9111 Email ayaz antmuh com TURKEY CECO Calcutta Tel 91 33 2248 5448 Em...