3. Wiring Method
3-5
3.3
Timing Diagram
3.3.1
Timing Diagram During Power Input
For L7 Series, connect single-phase power to the C1 and C2 terminals to supply power to
the control circuit, and three-phase power to L1, L2, and L3 to supply power to the main
circuit.
The servo signal becomes Ready after the maximum time of 120 [ms] that is required to
reset the inside of the device. If you change the signal to ON, the servo starts operation in 40
[ms].
Control power
establishment 5
[V]
Control program
reset
Main power
establishment
Alarm
(Normally On)
Servo Ready
Servo On
Clear DB
PWM output
(motor
rotation)
150 ms
50 ms
120 ms
10 ms
10 ms
5 ms
40 ms
Main power,
control power
supply
200 ms
2 ms