2. Installation
2-1
2.
Installation
2.1
Servo Motor
2.1.1
Usage Environment
Item
Requirements
Notes
Ambient
temperature
0
∼
40[
℃
]
If the temperature at which the product will be used is
outside this range, the product must be custom-ordered
with consultation of the technical support team.
Ambient
humidity
80[%] RH or lower
Use the product in steam-free places.
External
vibration
Vibration acceleration
19.6 [
㎨
] or below in the
X and Y directions
Excessive vibration reduces the lifespan of bearings.
2.1.2
Prevention of Excessive Shock
Excessive shock to the motor shaft during installation, or the motor falling during handling,
may damage the encoder.
2.1.3
Motor Connection
The motor might burn out when commercial power is directly connected to it.
Be sure to connect via the specified drive.
Connect the ground terminal of the motor to either of the two ground terminals inside the drive, and
the remaining terminal to the type-3 grounding.
Connect the U, V, and W terminals of the motor, just as the U, V, and W terminals of the drive.
Make sure that the pins on the motor connector are securely connected.
In case of moisture or condensation on the motor, make sure that insulation resistance is 10 [
㏁
]
(500 [V]) or higher before you start installation.
U
– U
V - V
W
– W
- F.G
Summary of Contents for L7 A001
Page 1: ...VER 1 5...
Page 2: ......
Page 32: ...1 Product Components and Signals 1 20...
Page 38: ...2 Installation 2 6...
Page 54: ......
Page 188: ...7 Product Specifications 7 26 L7 A020 L7 A035 Weight 2 5 kg cooling fan included...
Page 210: ...8 Maintenance and Inspection 8 14...
Page 211: ...9 Appendix 9 1 9 Appendix...
Page 218: ...9 Appendix 9 8...
Page 221: ......
Page 222: ......