5. Handling and Operation
5-1
5.
Handling and Operation
5.1
What to Check Before Operation
Thoroughly check the following to prevent injury or product damage from the operation of the
servo motor during test drive.
5.1.1
Wiring Check
1.
Is the voltage (AC 200 [V]) appropriate for the power input terminals?
2.
Are the power cables (U, V, W, and FG) between the drive and the motor connected correctly?
3.
Is the voltage of 24 [V] connected to control signals correctly?
4.
Is the regenerative resistance appropriate for the capacity and correctly connected?
5.
Are the wiring cables free from bends or dents?
6.
Are the grounding and shielding free from defects?
5.1.2
Drive Signal (CN1) Wiring Check
Make sure that the wiring and contact for drive signals are as in the following table:
Pin
Number
Pin Name
State of
Contact
Pin
Number
Pin Name
State of
Contact
18
EMG
ON
19
CWLIM
ON
47
SVON
OFF
20
CCWLIM
ON
48
STOP
OFF
17
ALMRST
OFF
The above is factory-initialized status. Different functions may be allocated according to input
signal allocations ([P2-00], [P2-01], [P2-02], [P2-03], and [P2-04]).
5.1.3
Surrounding Environment Check
Is there any metal powder or water around wires?
5.1.4
Machine Status Check
1.
Is the coupling of the servo motor in good condition?
2.
Are the locking bolts tightly screwed?
3.
Are there any obstacles in the machine operation area?
Summary of Contents for L7 A001
Page 1: ...VER 1 5...
Page 2: ......
Page 32: ...1 Product Components and Signals 1 20...
Page 38: ...2 Installation 2 6...
Page 54: ......
Page 188: ...7 Product Specifications 7 26 L7 A020 L7 A035 Weight 2 5 kg cooling fan included...
Page 210: ...8 Maintenance and Inspection 8 14...
Page 211: ...9 Appendix 9 1 9 Appendix...
Page 218: ...9 Appendix 9 8...
Page 221: ......
Page 222: ......