4. Parameters
4-45
4.2.8
Operation Handling Parameter
“**” Modification is not possible with the servo on & Power reset parameter.
“*” Parameter that cannot be modified with the servo on
Parameter
Unit
Initial
Details
Code
Name
Minimum Maximum
Cn-00
Manual JOG operation
-
-
The drive performs manual JOG operation
by itself.
(Refer to “Chapter 5 Handling and
Operation.”)
[MODE]: Finish
[UP]: Forward rotation (CCW)
[DOWN]: Reverse rotation (CW)
[SET]: Servo ON / OFF
Related parameters are as follows:
[P3-08]: Speed command acceleration
time
[P3-09]: Speed command deceleration
time
[P3-10]: Speed command S-curve
[P3-11]: Speed operation pattern
[P3-12]: JOG operation speed
Operate regardless of the contact input
status of CN1.
(Details: Refer to “4.4.5 Speed Operation
Parameter
Setting.”)
(Details: Refer to "5.2 Handling.")
Jog
-
-
Cn-01
Program JOG operation
-
-
Continuously operates according to the
program already set.
[SET]: Program JOG run or stop
Related parameters are as follows:
[P3-08]: Speed command acceleration
time
[P3-09]: Speed command deceleration
time
[P3-10]: Speed command S-curve
[P3-11]: Speed operation pattern
[P3-13~16]: Program operation speed 1
to 4
[P3-17~20]: Program operation time 1 to
4
Operate regardless of the contact input
status of CN1.
(Details: Refer to “4.4.5 Speed Operation
Parameter
Setting.”)
(Details: Refer to "5.2 Handling.")
Program jog
-
-
Cn-02
Alarm reset
-
-
Reset the alarm that went off.
(Details: Refer to "5.2 Handling.")
Alarm reset
-
-
Summary of Contents for L7 A001
Page 1: ...VER 1 5...
Page 2: ......
Page 32: ...1 Product Components and Signals 1 20...
Page 38: ...2 Installation 2 6...
Page 54: ......
Page 188: ...7 Product Specifications 7 26 L7 A020 L7 A035 Weight 2 5 kg cooling fan included...
Page 210: ...8 Maintenance and Inspection 8 14...
Page 211: ...9 Appendix 9 1 9 Appendix...
Page 218: ...9 Appendix 9 8...
Page 221: ......