3. Wiring Method
3-7
3.4
Control Signal Wiring
3.4.1
Contact Input Signal
Caution
1.
There are two input contacts based on the characteristics of individual signals: contact A and
contact B. They can be set by [P2-08] and [P2-09].
2.
It is possible to turn each contact on or off forcibly with [Cn-07]. Take extra caution, however,
because each contact is automatically turned off when power is off.
3.
The signal definition of each contact can be modified by [P2-00], [P2-01], [P2-02], [P2-03], and
[P2-04].
R2
Internal
Circuit
COM
R1
DC 24V
R1
: 3.3 KΩ, R2: 680 Ω