3. Wiring Method
3-3
3.2
Power Wiring
3.2.1
L7 Drive Wiring Diagram [L7SA001□ - L7SA035□]
U
V
W
L1
L2
L3
C1
C2
B+
B
BI
38
39
CN1
RA
M
E
Alarm-
Alarm+
1Ry
RA
1SK
1Ry
1MC
+24V
NF
1MC
R S T
서보드라이브
(200~230V)
Main
OFF
Main
ON
인코더
외부
회생저항
주1)
주2)
PO PI
DC 리액터
NOTE 1)
It takes approximately one to two seconds until alarm signal is output after you turn on the main
power. Accordingly, push and hold the main power ON switch for at least two seconds.
NOTE 2)
Short-circuit B and BI terminals before use. Regenerative resistance of L7SA001
□
-L7SA004
□
(50 [W], 100 [Ω]), L7SA010
□
(100 [W], 40 [Ω]), and L7SA035
□
(150 [W], 13 [Ω]) exist inside. If
regenerative capacity is high because of frequent acceleration and deceleration, open the short-
circuit pins (B, BI) and connect external regenerative resistance to B and B+.
NOTE 3)
Remove the sheath of cables to be used for the main circuit power by approximately 7-10 [
㎜
] and
use devoted crimp terminals. (Refer to “3.2.2 Power Circuit Electric Sub Assembly Standards.”)
NOTE 4)
Connect or remove the main circuit power unit wiring after pushing the button of the L7SA001
□
-
L7SA010
□
drive terminal. For drive L7SA035
□
, use a (-) slot screwdriver for connection and
removal.
Servo Drive
Note 1)
DC Reactor
Encoder
Note 2) External
Regenerative Resistancer
7~10
㎜
Summary of Contents for L7 A001
Page 1: ...VER 1 5...
Page 2: ......
Page 32: ...1 Product Components and Signals 1 20...
Page 38: ...2 Installation 2 6...
Page 54: ......
Page 188: ...7 Product Specifications 7 26 L7 A020 L7 A035 Weight 2 5 kg cooling fan included...
Page 210: ...8 Maintenance and Inspection 8 14...
Page 211: ...9 Appendix 9 1 9 Appendix...
Page 218: ...9 Appendix 9 8...
Page 221: ......
Page 222: ......