8. Maintenance and Inspection
8-13
(2) Graph of Overload during Stop
Load(%)
AL-21
Occurring
Time (sec)
MAX
MIN
Load(%)
AL-21
Occurring
Time (sec)
MAX
MIN
100% or
below
Infinite
110
7536.0
12057.6
4521.6
210
44.0
70.4
26.4
120
1884.0
3014.4
1130.4
220
36.0
57.6
21.6
130
837.3
1339.7
502.38
230
30.3
48.5
18.18
140
471.0
753.6
282.6
240
9.7
15.5
5.82
150
154.0
246.4
92.4
250
8.3
13.3
4.98
160
110.0
176.0
66
260
3.8
6.1
2.28
170
90.0
144.0
54
270
3.4
5.4
2.04
180
75.0
120.0
45
280
3.1
5.0
1.86
190
61.0
97.6
36.6
290
2.7
4.3
1.62
200
52.0
83.2
31.2
300
2.5
4.0
1.5
Load Curve During Stop
Load Factor (%)
T
im
e
(
s
e
c
)