8. Maintenance and Inspection
8-9
(2) Graph of Overload during Stop
Load (%)
AL-21
Occurring
Time (sec)
MAX
MIN
Load (%)
AL-21
Occurring
Time (sec)
MAX
MIN
100% or
below
Infinite
110
1372.8
2196.5
823.68
210
3.9
6.2
2.34
120
343.2
549.1
205.92
220
3.4
5.4
2.04
130
152.5
244.0
91.518
230
3.0
4.8
1.8
140
85.8
137.3
51.48
240
2.6
4.2
1.56
150
58.6
93.8
35.16
250
2.3
3.7
1.38
160
16.2
25.9
9.72
260
2.0
3.2
1.2
170
13.0
20.8
7.8
270
1.8
2.9
1.08
180
10.5
16.8
6.3
280
1.6
2.6
0.96
190
8.7
13.9
5.22
290
1.5
2.4
0.9
200
7.2
11.5
4.32
300
1.3
2.1
0.78
Load Curve during Stop 100 W or Lower SA Type