6. Communication Protocol
6-9
(5)
Read Each Block Register (0x6A)
Read values on the discontinuous register block (16-bit data).
Sending Packet
Normal Receiving Packet
Byte
Content
Value
Byte
Content
Value
0
Node ID
0x00
0
Node ID
0x00
1
Function
0x6A
1
Function
0x6A
2
Byte Count
0x06
2
Byte Count
0x06
3
Address Hi
0x00
3
Register Value Hi
0x02
4
Address Lo
0x01
4
Register Value Lo
0x2B
5
Address Hi
0x00
5
Register Value Hi
0x00
6
Address Lo
0x04
6
Register Value Lo
0x00
7
Address Hi
0x00
7
Register Value Hi
0x00
8
Address Lo
0x08
8
Register Value Lo
0x64
9
CRC Hi
9
CRC Hi
.
10
CRC Lo
10
CRC Lo
Error Receiving Packet
Byte
Content
Value
0
Node ID
0x00
1
Error Code
0x6A + 0x80
2
Exception Code
0x01 ~ 0x04
3
CRC Hi
4
CRC Lo
Example)
Node-ID
6A
06
01
00
02
CRC Hi
CRC Lo
04
00
0A
Request
Response
Slave Address (Node-ID)
Function Code
Byte Count
Address Hi (First)
Address Lo
Address Hi (Second)
Address Lo
Address Hi (Third)
Address Lo
CRC Hi
CRC Lo
Node-ID
6A
06
02
2B
00
CRC Hi
CRC Lo
00
00
05
Slave Address (Node-ID)
Function Code
Byte Count
Address
’
s Value Hi (First)
Address
’
s Value Lo
Address
’
s Value Hi (Second)
Address
’
s Value Lo
Address
’
s Value Hi (Third)
Address
’
s Value Lo
CRC Hi
CRC Lo
Summary of Contents for L7 A001
Page 1: ...VER 1 5...
Page 2: ......
Page 32: ...1 Product Components and Signals 1 20...
Page 38: ...2 Installation 2 6...
Page 54: ......
Page 188: ...7 Product Specifications 7 26 L7 A020 L7 A035 Weight 2 5 kg cooling fan included...
Page 210: ...8 Maintenance and Inspection 8 14...
Page 211: ...9 Appendix 9 1 9 Appendix...
Page 218: ...9 Appendix 9 8...
Page 221: ......
Page 222: ......