5. Handling and Operation
5-12
5.2.9
Output Contact Forced ON/OFF [Cn-08]
Without an upper level controller or I/O jig, the drive forcibly turns on/off the output contact.
(1)
Output Contact Forced ON/OFF Setting
The positions of the seven segment LEDs and CN1 contacts correspond as follows.
If an LED that corresponds to a contact is turned on/off, it indicates ON/OFF accordingly.
[Output Contact Setting]
Number
(5)
(4)
(3)
(2)
(1)
CN1 - pin
number
45
44
43
40 /41
38 / 39
Allocated default
signal name
INPOS
BRAKE
ZSPD
READY
ALARM
Press [UP] on each digit and the (4) and (2) signals are turned on or off for forced output.
Press [Down] on each digit and the (5), (3) and (1) signals are turned on or off for forced
output.
Press [MODE] to move to another digit.
(2)
Example of Output Contact Forced ON/OFF
(BRAKE OFF)
[Example of handling output contact forced ON/OFF]
Order
Loader Displays
Keys to Use
What to Do
1
Press [MODE] to move to [Cn-00].
2
Press [UP] or [DOWN] to move to
[Cn-08].
3
Press [SET] to enter input forced
ON/OFF setting.
4
Press [SET] to enter forced output bit
setting.