LS Industrial Systems Modbus TCP SV-iS7 Series User Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

* Use this board after read Safety Instruction of this manual carefully before 

using and follow the instructions exactly.   

* Please hand this user manual to end user and trouble shooting manager 

* After read this manual, keep it at handy for future reference

.

 

LS Industrial Systems 

Modbus TCP Option Board 

SV-iS7 Series 

Summary of Contents for Modbus TCP SV-iS7 Series

Page 1: ...this manual carefully before using and follow the instructions exactly Please hand this user manual to end user and trouble shooting manager After read this manual keep it at handy for future reference LS Industrial Systems Modbus TCP Option Board SV iS7 Series ...

Page 2: ...re to read and become familiar with the safety precautions at the beginning of this manual If you have any questions seek expert advice before you proceed Do not proceed if you are unsure of the safety precautions or any procedure WARNING z Be cautious about dealing with CMOS elements of option board It can cause malfunction by static electricity z Connection changing like communication wire chang...

Page 3: ...rk of the factory has to be connected to Internet through Gateway With simple wiring installation time can be reduced and maintenance becomes easier 2 Modbus TCP Technical features 3 Product Constituents Modbus TCP communication board 1 Modbus TCP manual 1 Fixed Screw M3 1 Transmission Speed 10Mbps 100Mbps Transmission method Baseband Max extended distance between nodes 100m Node Hub Max node numb...

Page 4: ...3 4 Modbus TCP Appearance and Installation 1 Appearance 2 Exterior CPU RJ45 Inverter Connector Debug Connector LINK SPEED ERROR CPU SW1 Protocol selecting switch Not used anymore LED Display LAN connector SW1 Inverter connector ...

Page 5: ...SV iS7 Modbus TCP Manual 4 3 Communication board connection to iS7 inverter ...

Page 6: ...r Make sure that cables connected to Pin3 and 6 are twisted together Pin No Signal Description Cable color 1 TX Transmitting data Plus White Yellow 2 TX Transmitting data Minus Yellow 3 RX Receiving data Plus White Green 4 NONE Not used Blue 5 NONE Not used White Blue 6 RX Receiving data Minus Green 7 NONE Not used White Brown 8 NONE Not used Brown 1 8 ...

Page 7: ...UTP U UTP High speed signal cable with no cover Maximum 200MHz Voice Information Data Low Video signal FTP S UTP Cable core covered only Maximum 100MHz Electromagnetic interruption EMI or electric stability considered Voice Information Data Low Video Video signal STP S STP Double covered separately covered Pair with cable core covered Maximum 500MHz Voice Information Data Video signal 75Ω coaxial ...

Page 8: ... The version of Communication card installed in inverter is displayed COM 09 FBus Led LED ON OFF information in Modbus TCP communication card is displayed COM 10 Opt Parameter1 0x0000 0x0000 0xFFFF Set IP Address COM 11 Opt Parameter2 0x0000 0x0000 0xFFFF COM 12 Opt Parameter3 0x0000 0x0000 0xFFFF Set Subnet Master COM 13 Opt Parameter4 0x0000 0x0000 0xFFFF COM 14 Opt Parameter5 0x0000 0x0000 0xFF...

Page 9: ...displayed automatically 3 FBus Led COM 09 Option card LED information displayed The ON OFF state of LINK SPD ERR CPU LED in Modbus TCP communication card is displayed at Keypad parameter COM 09 If you check COM 9 FBus LED with Keypad 4 LEDs can be seen According to order of LED of COM 09 Left Right LINK SPD ERR CPU LED can be displayed When LED is ON the relevant bit becomes 1 and when OFF it beco...

Page 10: ...r1 input 0xC4A8 For COM 11 Opt Parameter2 input 0x0A83 5 Modbus TCP Baud rate COM 16 Modbus TCP speed can be set within the range of 0 2 Automatic Speed Setting function is for setting automatically maximum speed in Network Full Duplex can transmit DATA through TX during receiving DATA through RX On the contrary Half Duplex can perform only one of RX or TX That is for maximum DATA transmitting and...

Page 11: ...n Modbus TCP can be divided into Client and Server Client gives the command and Server responds to the command Generally as Client there are PLC HMI PC so on and Server means inverter MBAP Header 7 bytes PDU 5 bytes Region Length Description Transaction Identifier 2 Bytes As an identified transmitting number is increased by 1 each time when Data frame is send to Server from Client Protocol Identif...

Page 12: ...ed Frame Length Value Function Code 1 Byte 0x03 Comm Address 2 Bytes 0x0000 0xFFFF Required Data number 2 Bytes 1 16 by LSIS Inverter standard Responded Frame Length Value Function Code 1 Byte 0x03 Comm Address 1 Byte 2 x Data required number Required Data number Data required number x 2 Bytes The required data number from communication address Required Frame Length Value Function Code 1 Byte 0x06...

Page 13: ...quired Frame to Server Exception Frame Structure Required Frame Length Value Function Code 1byte 0x10 Comm Address 2bytes 0x0000 0xFFFF Modifying Data number 2bytes 1 16 by LSIS inverter standard Byte Count 1byte 2 X Data number Data value to be modified Data number x 2 bytes Data for modifying Responded Frame Length Value Function Code 1 Byte 0x10 Comm Address 2 Bytes 0x0000 0xFFFF Modifying Data...

Page 14: ...or to be modified ILLEGAL DATA VALUE 0x03 If you try to modify Data with the value that is against the permitted data range SLAVE DEVICE FAILURE 0x04 If there is error in Server CAN Comm ERROR with inverter Option initialization ERROR failure of DATA comm with inverter SLAVE DEVICE BUSY 0x06 If Server can t respond due to other process such as Inverter parameter initialization or option initializa...

Page 15: ... is faulty Replace EEPRom CPU ERROR Flashing by turns Displayed if IP Address is set as 0 0 0 0 CPU ERROR are Flashing Displayed if CAN communication is interrupted CPU with 0 5 sec ERROR with 1sec period Flashing Displayed if Opt Parameter is changed and Comm Update Com94 is not done Speed Green ON means Comm Speed is 100Mbps OFF means Comm Speed is 10Mbps Link Green ON means it is ready to do co...

Page 16: ...ate is unidentified However the guarantee term may vary on the sales term z In warranty service information If the defective part has been identified under normal and proper use within the guarantee term contact your local authorized LS distributor or LS Service center z Out of warranty service information The guarantee will not apply in the following cases Troubles are attributable to a user s in...

Page 17: ...Hanoi Vietnam Tel 84 4 736 6270 1 Fax 84 4 736 6269 Dalian LS Industrial Systems co Ltd China Address No 15 Liaohexi 3 Road economic and technical development zone Dalian China e mail lixk lgis com cn Tel 86 411 8273 7777 Fax 86 411 8730 7560 LS Industrial Systems Shanghai Co Ltd China Address Room E G 12th Floor Huamin Empire Plaza No 726 West Yan an Road Shanghai China Tel 86 21 5237 9977 LS Ind...