![LS ELECTRIC SV-iS7 Series User Manual Download Page 167](http://html1.mh-extra.com/html/ls-electric/sv-is7-series/sv-is7-series_user-manual_1943801167.webp)
Basic Functions
150
7.1.5
Setting a Frequency with Pulse Input (with an optional
encoder module)
After installing an optional encoder module, you can set a frequency reference by setting DRV-
07 (Frequency reference source
) to “9 (Pulse)” and provid
ing a pulse frequency of 0
–
32.00 kHz
to the pulse input terminal.
Group Code Name
LCD Display Parameter Setting Setting Range Unit
DRV
07
Frequency reference
source
Freq Ref Src 7
Encoder
0
–
9
-
IN
01
Frequency at maximum
analog input
Freq at
100%
60.00
0.00
–
max.
frequency
Hz
APO
01
Encoder option mode
Enc Opt
Mode
2
Reference 0-2
-
04
Encoder type selection Enc Type Sel 0
-
0-2
-
05
Encoder pulse selection
Enc Pulse
Sel
2
A
0-2
-
06
Encoder pulse number
Enc Pulse
Num
-
10-5000
-
09
Pulse input display
Pulse
Monitor
-
-
kHz
10
Encoder filter time
constant
Enc Filter
10
0-10000
ms
93
Minimum pulse input
Enc Pulse x1 0.0
0-100
kHz
94
Minimum pulse
Output%
Enc Perc Y1 0.00
0-100
%
95
Maximum pulse input
Enc Pulse x2 100.0
0-200
kHz
96
Maximum pulse
Output%
Enc Perc y2 100.00
0-100
%
*
Quantizing is disabled if “0” is selected.
Summary of Contents for SV-iS7 Series
Page 17: ......
Page 114: ...Peripheral Devices 97 Group 2 ...
Page 115: ...Peripheral Devices 98 Group 3 ...
Page 116: ...Peripheral Devices 99 Group 4 ...
Page 159: ...Basic Functions 142 Code Description V1 Quantizing ...
Page 465: ...Safety Funtion STO Safe Torque Off 448 14 2 1 Safety Function Wiring Diagram ...