201
Maintenance
6.2
Replacing Major Components
Refer to following for information on replacing major components.
Exchange Cycle for Major Components
Following table shows the cycles and information for major components.
Components
Exchange standard
Symptom
Action
Cooling fan
3 years
Spinning failure
Make inquiries to the A/S center
and replace it with a new
product.
Main circuit electrolytic
condenser
3 years
Capacity
reduction
Make inquiries to the A/S center
and replace it with a new
product.
Main circuit relay
-
Operation
failure
Make inquiries to the A/S
center.
Note
The life times of major components are based on the operating rated load consecutively. The
lifetime may be different according to conditions and environment.
6.3
Storage and Disposal
Storage
If you are not using the product for an extended period, store it in the following way:
•
Store the product in the same environmental conditions as specified for operation (refer
to
1.3 Installation Considerations
•
When storing the product for a period longer than 3 months, store it between 10
˚
C and
30
˚
C, to prevent depletion of the electrolytic capacitor.
•
Do not expose the inverter to snow, rain, fog, or dust.
•
Package the inverter in a way that prevents contact with moisture. Keep the moisture
level below 70% in the package by including a desiccant, such as silica gel.
Summary of Contents for LSLV-S100 Series
Page 1: ......
Page 11: ...Preparing the Installation 2 ...
Page 13: ...Preparing the Installation 4 5 5 22kW 3 Phase ...
Page 16: ...Preparing the Installation 7 Front cover removed ...
Page 45: ...Installing the Inverter 36 IP66 0 4 0 8kW 3 phase 1 5 2 2kW 3 phase ...
Page 50: ...Installing the Inverter 41 0 4 22kW Standard I O Multiple I O ...
Page 67: ...Installing the Inverter 58 ...
Page 69: ...Learning to Perform Basic Operations 60 30 75kW Models ...
Page 193: ...Table of Functions 184 ...
Page 205: ...196 Troubleshooting ...
Page 228: ...Technical Specification 219 30 75kW Models 30 kW 3 Phase 37 45 kW 3 Phase ...
Page 230: ...Technical Specification 221 IP66 Models 0 4 4 0kW NP Non PDS type ...
Page 231: ...Technical Specification 222 0 4 4 0kW PDS type ...
Page 233: ...Technical Specification 224 5 5 7 5kW NP Non PDS type ...
Page 235: ...Technical Specification 226 11 0 22 0kW NP Non PDS type ...
Page 259: ...250 ...
Page 261: ...252 ...
Page 263: ...254 ...