Table of Display Modes
The following table lists the 5 display modes used to control the inverter functions.
Mode Name
Keypad
Display
Description
Monitor mode
MON
Displays the in
verter’s operation status information. In
this mode, information including the inverter’s
frequency reference, operation frequency, output
current, and voltage may be monitored.
Parameter mode
PAR
Used to configure the functions required to operate the
inverter. These functions are divided into 14 groups
based on purpose and complexity.
User & Macro
mode
U&M
Used to define User groups and Macro groups. These
user-definable groups allow specific functions of the
inverter to be grouped and managed in separate
groups.
This mode is not displayed when you navigate through
the modes if no user groups or Macro groups have
been defined.
Trip mode
TRP
Used to monitor the inverter’s fault trip information,
including the previous fault trip history.
When a fault trip occurs during inverter operation, the
operation frequency, output current, and output voltage
of the inverter at the time of the fault may be monitored.
This mode is not displayed if the inverter is not at fault
and fault trip history does not exist.
Config mode
CNF
Used to configure the inverter features that are not
directly related to the operation of the inverter. The
settings you can configure in the Config mode include
keypad display language options, monitor mode
environment settings, communication module display
settings, and parameter duplication and initialization.
Summary of Contents for LSLV-H100 Series
Page 17: ...Preparing the Installation 4 37 90 kW 3 Phase ...
Page 18: ...Preparing the Installation 5 110 132 kW 3 Phase ...
Page 19: ...Preparing the Installation 6 160 185 kW 3 Phase ...
Page 20: ...Preparing the Installation 7 220 250 kW 3 Phase ...
Page 21: ...Preparing the Installation 8 315 400 kW 3 Phase ...
Page 22: ...Preparing the Installation 9 500 kW 3 Phase ...
Page 35: ...Installing the Inverter 22 ...
Page 50: ...37 Installing the Inverter Input and Output Control Terminal Block Wiring Diagram ...
Page 104: ...91 Learning Basic Features 0 10 V Input Voltage Setting Details V1 Quantizing ...
Page 181: ...168 Learning Advanced Features PID Command Block ...
Page 182: ...169 Learning Advanced Features ...
Page 183: ...170 Learning Advanced Features PID Feedback Block ...
Page 184: ...171 Learning Advanced Features PID Output Block ...
Page 185: ...172 Learning Advanced Features PID Output Mode Block ...
Page 198: ...185 Learning Advanced Features EPID1 Control block ...
Page 199: ...186 Learning Advanced Features EPID2 Control block ...
Page 220: ...207 Learning Advanced Features ...
Page 235: ...222 Learning Advanced Features The Time Chart for the Exception Day ...
Page 506: ...Table of Functions 493 ...
Page 520: ...Table of Functions 507 8 16 4 Cooling Tower MC4 Group ...
Page 549: ...Troubleshooting 536 ...
Page 569: ...Technical Specification 556 11 3 External Dimensions 0 75 30 kW 3 phase 37 90 kW 3 phase ...
Page 570: ...Technical Specification 557 110 185 kW 3 phase ...
Page 601: ...588 ...
Page 602: ...589 ...
Page 603: ...590 ...