Appendix
48
ProtoMat M60
Before switching on, always check that the head and motor cables are in
the correct place.
The fuses in the primary current circuit are in the power switch, which
also contains the mains filter and the power selector (e.g. 230 V/115 V).
The fuses should be medium semi-time lag:
• 230V fused with 3.15A/T
• 115V fused with 3.15A/T
8.9 The LPKF ProtoMat M60 Commands
8.9.1 Command structure
The SMCU (
S
ignal
P
rocessor
C
ontrol
U
nit) control unit of the machine
interprets the HP-GL commands described below and converts them
into set reactions.
The resolution of the machine is 0.0079375mm. This is a different
resolution than that of standard HP-GL-plotters. Therefore the output is
scaled down when original commands are used.
The syntax:
The SMCU expects a separator between the command parameters
which is not any of the figures or upper case letterscapitals. A new
command can follow a parameter without a separator. The last character
in a command file which is sent must be a semicolon or a line feed
symbol (0A hex.).
Unknown commands are ignored by the control unit, but their
parameters can lead to unwanted plot absolute or plot relative
commands.
Symbol
Meaning
{...}
The contents can be repeated any number of times
()
The command parameters are between these brackets.
[]
The content of these brackets is optional and does not
have to be included.