8.3.4 Maintaining the hand pump
For the first time, the oil should be changed after six months and then
once a year. For the oil change procedure and the use of the correct
hydraulic oil, contact the LPKF Support.
Topping up with hydraulic oil
›
Make sure that the manometer shows 0 bar/psi.
It may be necessary to let down the pressure by rotating the
handwheel on the pump counter clockwise.
›
To close the pressure relief valve, rotate the handwheel clockwise as
far as it will go.
›
Unscrew the spigot nut of the hydraulic hose at the connecting pipe
of the hand pump and pull off the hydraulic hose.
›
Remove the screw cap of the oil tank.
›
To drain the oil from the hand pump:
– By tilting the device, pour the oil into a oil catchment tray or
container.
– To meet environmental standards, fill the used oil into a container
adequate for disposal.
›
Fill the oil tank with an approved type of oil up to about 2.0-2.5 cm
below the top tank rim. (see chapter 8.3.1‚ "Approved hydraulic oils",
›
Open the pressure relief valve and actuate the pump lever several
times, to ventilate the oil tank.
›
After ventilation, check the oil level again.
›
Screw on the oil tank cap and tighten it by hand.
The hand pump can be installed again and put into operation (see
chapter 3‚ "Installation/Putting into operation", on page 21).
Summary of Contents for MultiPress S
Page 2: ......
Page 12: ...For your notes 10 MultiPress S Operating manual 3 0 Issued 3 6 2009...
Page 15: ...Table of contents MultiPress S Operating manual 3 0 Rev 3 6 2009 13 13 Index 73...
Page 30: ...For your notes 28 MultiPress S Operating manual 3 0 Issued 3 6 2009...
Page 38: ...For your notes 36 MultiPress S Operating manual 3 0 Issued 3 6 2009...
Page 58: ...For your notes 56 MultiPress S Operating manual 3 0 Issued 3 6 2009...
Page 60: ...For your notes 58 MultiPress S Operating manual 3 0 Issued 3 6 2009...
Page 70: ...Technical Data 68 MultiPress S Operating manual 3 0 Rev 3 6 2009...