background image

Installation & Operation 

manual

Elite 5X DSI,  Mark 5X DSI, Elite 4X DSI & Mark 4X DSI

Operation manual

DSI ONLY COVER_.indd   1

9/13/2011   9:44:15 PM

Summary of Contents for Elite 4X DSI

Page 1: ...Installation Operation manual Elite 5X DSI Mark 5X DSI Elite 4X DSI Mark 4X DSI Operation manual DSI ONLY COVER_ indd 1 9 13 2011 9 44 15 PM...

Page 2: ...ico Navico may find it necessary to change or end our policies regulations and special offers at any time We reserve the right to do so without notice All features and specifications subject to change...

Page 3: ...ialogs 5 Cursor 5 Standby mode 6 Restore defaults 6 Adjusting the display 6 Pages 7 DSI Page 7 Split Frequency 7 Split Zoom 8 Overlay Data 8 Using DSI 10 Trackback 10 DSI menu 10 DSI Interpretation 14...

Page 4: ...levels Muting Audio Select Mute Audio from the System menu and press Enter Unit Controls LIGHT POWER controls backlight level and turns unit on off KEYPAD controls cursor selects items on menus PAGES...

Page 5: ...the first time To choose your own settings do not run the setup wizard To restart the Setup wizard restore defaults DSI menu Accessing the Settings menu DSI page DSI menu Pages This unit has three pa...

Page 6: ...options and settings including scrollbars on off features and dropdown menus Scrollbars Select the scrollbar and press the keypad left decrease or right in crease On Off features Select an on off men...

Page 7: ...ct review sonar history Press Menu and select Exit cursor mode to clear the cursor Dialogs Dialogs are used for user input or for presenting in formation to the user Depending on the type of infor mat...

Page 8: ...Enter Press any key to resume normal operation Restore defaults Resets unit options and settings to defaults NOTE Leaving your unit in Standby mode when your boat is not is use will run down your bat...

Page 9: ...ht to left on your unit s screen DSI Split Frequency page Split Frequency Displays both transducer frequencies at the same time 800 kHz provides the best resolution while 455 kHz has greater depth cov...

Page 10: ...red overlay data using the Show setting Show Enables disables the display of overlay data allow ing you to remove overlay data from the screen without deleting the selected overlay data con figuration...

Page 11: ...s Enter 5 Select the desired data from the Con figure Items to show screen Press En ter 6 Press Menu and select Return to overlays 7 Press Menu select Done Configuring and press Enter Customizing Over...

Page 12: ...and the sonar history bar appears at the bottom of the screen Move the sonar history bar all the way to the right to resume normal sonar scrolling or press Menu and select Exit cursor mode DSI histor...

Page 13: ...you to adjust contrast settings Range Selects the deepest range shown on the display Range settings display the sec tion of the water column from the water surface to the selected depth range Custom R...

Page 14: ...unit 800 kHz offers the best resolution while 455 kHz has greater depth coverage Surface Clarity Surface Clarity reduces surface clutter by decreas ing the sensitivity of the receiver near the surface...

Page 15: ...you to select data water temperature depth etc to be displayed on top of the DSI screen Overlay data setup is covered in the Pages section Settings Accesses the settings menu Overlay data DSI only in...

Page 16: ...14 DSI Interpretation Baitball Bridge piling Pipes Baitfish on the move DSI only indb 14 9 14 2011 7 17 51 PM...

Page 17: ...15 DSI Interpretation Fish Trees Fish Thermocline Structure Structure DSI only indb 15 9 14 2011 7 17 52 PM...

Page 18: ...on and configuration settings for your unit System Adjusts unit settings like language mute audio and advanced mode Settings menu Displays soft ware informa tion Turns on off unit audio System menu Se...

Page 19: ...it Be fore attempting a software update you can check the version of software your unit is using by access ing the About screen Lowrance periodically updates unit software to add features and improve...

Page 20: ...the bottom depth is out of transducer range When the unit is in manual mode you may not re ceive any depth readings or you may recieve incor rect depth information Installation Provides access to Kee...

Page 21: ...ter activity Keel Transducer Keel Offset 3 5 feet Before setting keel offset measure the distance from the transducer to the lowest part of the keel If for example the keel is 3 5 feet below the trans...

Page 22: ...ction 18 O On Off features 4 Overlay Data 8 13 Configure 9 Customizing 9 Show 8 R Range 11 Reset water distance 19 Restore defaults 6 Restore Defaults 17 S Scrollbars 4 Settings Menu 16 Setup wizard 3...

Page 23: ...Backlight Cold cathode fluorescent lamp 10 levels Power Transmit Power 4000W PTP 500W RMS Power Requirement 12 Volts DC Voltage Input 10 to 17V Current drain Elite 5x at 13 5V 630mA Mark 5x at 13 5V 3...

Page 24: ...CD Backlight White LED 10 levels Power Transmit Power 2800W PTP 350W RMS Power Requirement 12V Voltage Input 10 to 17V Current drain at 13 5V 200mA Fuse type 3 amp Automotive not supplied DSI Sonar Ma...

Page 25: ...r you see the instructions in paragraph number 1 below Accessory Ordering Information LEI Extras is the accessory source for sonar and GPS products manufactured by Lowrance Electronics To order Lowran...

Page 26: ...Copyright 2011 All Rights Reserved Navico Holding AS 988 10149 001 Visit our website www lowrance com DSI ONLY COVER_ indd 4 9 13 2011 9 44 16 PM...

Reviews:

Related manuals for Elite 4X DSI