DME D120 T1

WARNING! 

– Carefully read the manual before the installation or use.
– This equipment is to be installed by qualified personnel, complying to current standards, to avoid

damages or safety hazards. 

– Remove eventual dangerous voltage from the product before any maintenance  operation on it.
– The manufacturer cannot be held responsible for electrical safety in case of improper use of the

equipment.

– Products illustrated herein are subject to alteration and changes without prior notice. Technical data

and descriptions in the documentation are accurate, to the best of our knowledge, but no liabilities for
errors, omissions or contingencies arising therefrom are accepted.

– A circuit breaker  must be included in the electrical installation of the building. It must be installed

close by the equipment and within easy reach of the operator.
It must be marked as the disconnecting device of the equipment: IEC /EN 61010-1 § 6.11.

– Fit the instrument in an enclosure or cabinet with minimum IP51 degree protection.
– Clean the instrument with a soft dry cloth, do not use abrasives, liquid detergents  or solvents.

INDEX

PAGE

Introduction ........................................................................................................................................

1

Description ..........................................................................................................................................

1

Selection of readings...........................................................................................................................

2

Metrological LED .................................................................................................................................

2

Energy  flow indication........................................................................................................................

2

Programmable static output................................................................................................................

2

Incorrect wiring indication...................................................................................................................

2

Navigation with front key  ...................................................................................................................

2

Advanced functions .............................................................................................................................

3

Parameter setting (setup)....................................................................................................................

4

Setup parameter table .........................................................................................................................

4

Mechanical dimensions (mm) .............................................................................................................

5

Wiring diagrams..................................................................................................................................

5

Technical characteristics......................................................................................................................

6

INTRODUCTION
The DME D120T1 is a single-phase active and reactive energy meter for direct connection, for currents
up to 63A.
The energy accuracy is compliant with reference standard IEC/EN 62053-21 Class 1.
Apart from energy metering, it can measure additional indications, for a total of 14 measurements that
can be visualized on the large backlighted LCD display. 
The DME D120 T1 has a standard 2U (36mm wide) modular housing and is supplied with sealable
terminal blocks.

DESCRIPTION
–   Modular DIN-rail housing, 2U (36mm wide)
–   Direct connection for currents up to 63A
–   Active energy measure complies IEC/EN 62053-21 Class 1
–   LCD display with backlight
–   Counter with 6+1 digits
–   Button for measure selection and programming
–   Total active and reactive energy meters
–   Partial active and reactive energy meters, resettable
–   Hour counter, total and partial
–   Pulse LED for active energy consumption
–   Indication of instantaneous consumption (active power)
–   Programmable static output, for pulse or alarm threshold.

ATTENZIONE!! 

– Leggere attentamente il manuale prima dell’utilizzo e l’installazione.
– Questi apparecchi devono essere installati da personale qualificato, nel rispetto delle vigenti normative

impiantistiche, allo scopo di evitare danni a persone o cose. 

– Prima di qualsiasi intervento sull’apparecchio, rimuovere eventuali tensioni pericolose

dall’apparecchio

– Il costruttore non si assume responsabilità in merito alla sicurezza elettrica in caso di utilizzo

improprio del dispositivo.

– I prodotti descritti in questo documento sono suscettibili in qualsiasi momento di evoluzioni o di

modifiche. Le descrizioni ed i dati a  catalogo non possono pertanto avere alcun valore contrattuale.

– Un interruttore o disgiuntore va compreso nell’impianto  elettrico dell’edificio. Esso deve trovarsi in

stretta vicinanza dell’apparecchio ed essere facilmente raggiungibile da parte dell’operatore. Deve
essere marchiato come il dispositivo di interruzione dell’apparecchio: IEC/ EN 61010-1 § 6.11.

– Installare lo strumento in contenitore e/o quadro elettrico con grado di protezione minima IP51.
– Pulire lo strumento con panno morbido, non usare prodotti abrasivi, detergenti liquidi o solventi.

INDICE

PAGINA

Introduzione ........................................................................................................................................

1

Descrizione .........................................................................................................................................

1

Selezione misure .................................................................................................................................

2

LED metrologico..................................................................................................................................

2

Indicazione flusso energia ...................................................................................................................

2

Uscita statica programmabile..............................................................................................................

2

Indicazione collegamento errato..........................................................................................................

2

Navigazione tramite tasto frontale .......................................................................................................

2

Funzioni avanzate ................................................................................................................................

3

Impostazione parametri (setup) ..........................................................................................................

4

Tabella parametri di setup ...................................................................................................................

4

Dimensioni meccaniche (mm).............................................................................................................

5

Schemi di collegamento ......................................................................................................................

5

Caratteristiche tecniche .......................................................................................................................

7

INTRODUZIONE
Il DME D120T1 è un contatore di energia monofase per inserzione diretta, per correnti fino a 63A. 
La misurazione dell’energia è conforme alla norma IEC/EN 62053-21 classe 1.
Oltre alla misurazione dell’energia, è in grado di fornire ulteriori indicazioni, per un totale di 14 misure,
che possono essere visualizzati sull’ampio display LCD retroilluminato. 
Il DME D120 T1 ha un contenitore modulare standard di larghezza 2U (36 mm) ed è fornito di serie di
coprimorsetti piombabili.

DESCRIZIONE
–   Esecuzione modulare 2U (36mm) per guida DIN.
–   Inserzione diretta per correnti max 63A.
–   Misura energia attiva conforme a IEC/EN 62053-21 classe 1.
–   Display LCD retroilluminato.
–   Contatore con 6+1 cifre.
–   Tasto per la selezione delle misure e programmazione.
–   Contatori di energia attiva e reattiva totali.
–   Contatori di energia parziali azzerabili.
–   Contaore totale e parziale.
–   LED frontale a impulsi per energia attiva consumata.
–   Indicazione consumo istantaneo (potenza attiva).
–   Uscita statica programmabile per impulsi o soglia di allarme.

SINGLE-PHASE DIRECT CONNECTION ENERGY METER

Instruction manual

GB

CONTATORE DI ENERGIA MONOFASE A INSERZIONE DIRETTA

Manuale operativo

I

Summary of Contents for DME D120 T1

Page 1: ... consumption active power Programmable static output for pulse or alarm threshold ATTENZIONE Leggere attentamente il manuale prima dell utilizzo e l installazione Questi apparecchi devono essere installati da personale qualificato nel rispetto delle vigenti normative impiantistiche allo scopo di evitare danni a persone o cose Prima di qualsiasi intervento sull apparecchio rimuovere eventuali tensi...

Page 2: ... della accuratezza dell energy meter INDICAZIONE FLUSSO DI ENERGIA Quando lo strumento sta rilevando un flusso di energia verso il carico il display visualizza nell angolo in alto a destra una icona rotante Quando il carico non richiede energia attiva oppure quando la corrente assorbita è inferiore alla corrente di avviamento l icona rotante scompare USCITA STATICA ISOLATA PROGRAMMABILE L uscita s...

Page 3: ...k CLEAR P clearing of partial energy meters CLEAR h clearing of partial hour counter if enabled CLEAR d clearing of max demand values if enabled SETUP parameter programming setup INFO revision and checksum of internal software ESC returns to normal operation 5 To select a function press while the required function is displayed 6 If the button is never pressed for 60 consecutive seconds the display...

Page 4: ...ined by P 03 is higher than P 04 end de activates when its value becomes less than P 06 maximum limit with hysteresis If P 04 P 06 then output activates when the measure defined by P 03 is lower than P 04 end activates when its value becomes higher than P 06 minimum limit with hysteresis P 03 Selection of measure to compare with thresholds P 04 e P 05 Threshold and delay for output activation Note...

Page 5: ... 5 MECHANICAL DIMENSIONS mm 5 43 7 63 35 8 90 44 7 92 5 DIMENSIONI MECCANICHE mm WIRING DIAGRAMS O1 O1 Static output 30VDC 50mA max L L N O1 O1 L LOAD N L LINE N L L N O1 O1 L L O1 N O1 _ NPN out PNP out SCHEMI DI COLLEGAMENTO ...

Page 6: ...1 To comply with the protection requirements the meter must be mounted in a class IP51 enclosure or better IEC EN 60529 TECHNICAL CHARACTERISTICS Standard version Rated voltage Us 220 240V Operating voltage range 187 264V Rated frequency 50 60Hz Operating frequency range 45 66Hz Power consumption dissipation 7VA 0 45W A120 version Rated voltage Us 110 120V Operating voltage range 93 132V Rated fre...

Page 7: ...mento deve essere installato in contenitore con grado di protezione minimo IP51 IEC EN 60529 CARATTERISTICHE TECNICHE Versione standard Tensione nominale Us 220 240V Limiti di funzionamento 187 264V Frequenza nominale 50 60Hz Limiti di funzionamento 45 66Hz Potenza assorbita dissipata 7VA 0 45W Versioni A120 Tensione nominale Us 110 120V Limiti di funzionamento 93 132V Frequenza nominale 60Hz Limi...

Reviews: