MOTOR TORQUE/SPEED: 0.7NM/34RPM
• Motor is combined with a wired switch and powered by a battery wand.
• The side of the motor mount with the SETTING button should face you.
• Please replace batteries when the motor alarm sounds
OPERATION
1. Press the red setting button on the motor until the motor beeps 6 times
2. Check the motor direction by pressing UP or DOWN on the switch
3. If correct then proceed to set-up lower limit, if incorrect change the motor direction by pressing the CONFIRM button 6 times on the
wand control and the motor will beep 2 times changing the direction of the blind
SET-UP LOWER LIMIT
1. Press DOWN button on the wand control to lower the blind to the
desired level and then press DOWN button again to stop the blind.
2. Press DOWN button repeatedly to adjust the blind level more
accurately, then press CONFIRM button and the motor will beep
once to set the lower limit.
SET-UP UPPER LIMIT
1. Press UP button on the wand control to lower the blind to
the desired level and then press UP button again to stop the
blind.
2. Press UP button repeatedly to adjust the blind level more
accurately, then press CONFIRM button and the motor will
beep once to set the lower limit.
Up Button
Setting Button (Red)
Confirm
Button
Down Button
S E T- U P A N D O P E R A T I O N
R 1 7 0 5 / R 1 7 0 6
programming instuctions