Lotus FTLD-85GS Installation And Operating Instructions Manual Download Page 18

MAINTENANCE

Translation of the original instructions

18

6 MAINTENANCE

6.1

Routine

When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation.
We therefore recommend stipulating a service contract.
 

Caution

 

Maintenance  must  only  be  performed  by  specialist  personnel  in  compliance  with  current
regulations and our own instructions.

 

Before carrying out any maintenance and/or cleaning operation:
 

·

Disconnect the appliance from the mains power supply and/or close the gas.

·

Wait for a sufficient time for the appliance to cool down.

·

Do not wash the appliance with direct or high-pressure jets of water, since any infiltration of water into the

electrical components could jeopardise correct operation of the appliance and its safety systems.

 

Warning

 

For maintenance/replacement of components, order and use only original spare parts.

 

Replacing parts must exclusively be performed by authorised and/or qualified personnel. When replacing the
electrical components of the machine and the electrical panels, scrupulously follow the technical
characteristics for the replacement component indicated on the component itself. The appliance does not
require any special maintenance but during the use of the equipment it is advisable to check the following at
least once a year (possibly increasing the frequency depending on the degree of use):
 

·

The status of connections especially on the terminal board and the power supply cable, as well as the

status of the gas connections;

·

The operating condition of the various components (perform a functional test);

·

For appliances fitted with rotary resistances, remove the hub, grease it and replace the three o-ring seals

to avoid possible leaks.

6.2

Replacing the main burner nozzle

·

Remove the front screws fastening the dashboard/panel and pull it outwards

·

Detach the starter cable

·

Using a suitable wrench, unscrew the nozzle and replace it with an appropriate new one

·

The main burner does not require any regulation of the primary air

 

6.3

Replacing the pilot burner nozzle

The pilot burner flame has a fixed air supply. The only necessary item is replacement of the nozzle
depending on the type of gas used (see technical data table).
 

·

Unscrew the coupling connecting the pilot tube to the pilot itself and slide out the nozzle to be replaced

·

Replace the nozzle with the appropriate version and make sure that, after ignition, the flame correctly

touches the tip of the thermocouple

 

Summary of Contents for FTLD-85GS

Page 1: ...NAL USE FTLD 85GS FTRD 85GS FTLD 87GS FTLRD 87GS FTRD 87GS FTLD 89GS FTLRD 89GS FTRD 89GS FTLD 95GS FTRD 95GS FTLD 99GS FTLRD 99GS FTRD 99GS Model LIBR ISTR FTD G Code 563047000 Review 1 Edition date...

Page 2: ...ation 9 3 4 Electrical gas connections 9 3 5 Water connection and drainage 14 4 BURNERS TECHNICAL DATA TABLE ITGB 15 4 1 Burners technical data table 15 5 INSTRUCTIONS FOR USE 16 5 1 General informati...

Page 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 FTD G...

Page 4: ...E mm AIR INPUT cm FT D 85G 500 800 597 5 77 3 105 150 FT D 87G 700 800 597 5 77 3 105 220 FT D 89G 900 800 597 5 87 1 450 300 FT D 95G 500 950 719 77 3 105 345 FT D 99G 900 950 719 87 1 450 490 B Elec...

Page 5: ...ation of the original instructions 5 1 2 Components FIG A 1 Valve knob 2 Dashboard bracket 3 Piezoelectric 4 Valve 5 Gas pipes 6 Extends drainage 7 Pilot 8 Ignition spark plug 9 Injector 10 Bracket 11...

Page 6: ...Translation of the original instructions 6 FIG B 1 Bracket 2 Pilot light nozzle 3 Ignition spark plug 4 Extends drainage WIRING DIAGRAM FTDG 1 Power supply terminal board 2 Power button 3 4 Ignition...

Page 7: ...electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be hel...

Page 8: ...llection The penalties provided for in the event of improper disposal of RAEE Waste Electrical and Electronic Equipment are those provided for by the national transpositions of European Directives 201...

Page 9: ...nding the heat emitted by this appliance Connect the water supply if necessary Caution Do not install the appliance near equipment machines used in cold processes If the appliance has to be installed...

Page 10: ...lls made of flammable material furthermore appropriate measures should also be adopted to ensure the thermal insulation of flammable parts such as the installation of heat shields take special care to...

Page 11: ...es this gas To adapt the appliance to another type of gas make sure that the type of gas in question complies with the information in this instruction manual Warning Pressure is measured with a pressu...

Page 12: ...standard In the case of forced evacuation The gas supply to the appliance must be directly servo controlled by the system and must stop if the flow rate drops below the values indicated in point 4 3...

Page 13: ...the original instructions 13 1 Windproof fume stack fig 3 Extractor hood fig 4 2 Servo system B11 type appliances are supplied on request with a hood or a hood and windproof fume stack to be assemble...

Page 14: ...r siphons Water is discharged by free fall so it is essential that the height of the drain is lower than the point of exit of the pipe The water discharge pipe also conveys cooking fat If the drain is...

Page 15: ...h 0 741 FT D 87GS Burner injector 1 100 mm 3 x 87 3 x 87 3 x 135A Pilot injector 1 100 mm 1 x 19 1 x 19 1 x 27 Consumption kg h 0 828 kg h 0 816 m3 st h 1 111 FT D 89GS 2 burner 7 kW Burner injector...

Page 16: ...ody to avoid burns caused by high temperatures After switching off the appliance wait for a sufficient time for it to cool before carrying out any cleaning or maintenance operation If smoke is emitted...

Page 17: ...ion 0 This control blocks the gas supply to both the main burner and the pilot burner 5 6 Observations and advice In the case of appliances with two cooking zones it is possible to set different tempe...

Page 18: ...dicated on the component itself The appliance does not require any special maintenance but during the use of the equipment it is advisable to check the following at least once a year possibly increasi...

Page 19: ...ront panel unscrew the gas connection screw couplings and extract the valve bulb then replace the faulty parts and install the new ones in sequence THERMOCOUPLE fig A pos 6 unscrew the pilot burner co...

Page 20: ...are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For m...

Reviews: