Lotus FMPG-20 Installation And Operating Instructions Manual Download Page 5

GENERAL INFORMATION

Translation of the original instructions

5

2 GENERAL INFORMATION

2.1

Declaration of compliance

The manufacturer declares that the appliances comply with the requirements of the regulation GAR
2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be
performed in compliance with current regulations, especially with regard to ventilation of the premises and
the exhaust gas evacuation system.
 

·

Read the warnings in this manual carefully. They provide important information about safe installation,

use and maintenance.

·

The instruction manual must be kept for the entire duration of the equipment and made available to users

for every possible consultation. The manual should be consulted for any information concerning
installation, use and maintenance of the appliance.

·

After removing the packaging, check the integrity of the equipment.

·

All packaging materials (plastic bags, polystyrene, staples, etc.) must be disposed of in compliance with

current regulations.

·

Before connecting the appliance, make sure that the information on the data plate matches the electricity

and gas mains where the appliance is installed. The manufacturer accepts no liability if the
equipment is not connected in accordance with current regulations.

·

Always keep all parts of the equipment clean to avoid the risk of oxidation/rust and/or aggression by

chemical agents.

·

The equipment must only be used by personnel trained for the purpose.

·

The installation must be implemented by professionally qualified personnel in accordance with

the manufacturer's instructions and current reference standards.

·

The electrical safety of this equipment is only ensured when it is correctly connected to an effective

ground/earth system as required by current electrical safety standards. The manufacturer cannot be held
liable for any damage caused if the system is not connected to ground/earth.

·

Before carrying out any cleaning or maintenance tasks on the equipment, unplug it from the electricity

mains. In the event of faults or malfunctions, always deactivate the appliance.

·

Repair work of any kind must only be performed by qualified personnel.

·

This appliance must only be used for its expressly intended purpose for cooking or heating food. Any

other use is considered improper.

·

The appliance is intended for professional use and must be used by trained personnel.

·

The installation and possible transformation to another power supply voltage (if envisaged), or

transformation for operation with another type of gas, must be implemented exclusively by qualified and
authorised professional personnel.

·

Before using the appliance, carefully clean all surfaces intended to come into contact with food.

·

The manufacturer declines any and all liability for any direct or indirect damage resulting from improper

use of the equipment. The manufacturer declines any and all liability for damage caused by incorrect
installation, tampering, poor maintenance and unskilled use. Moreover, the manufacturer declines any
liability for possible inaccuracies that may be contained in this booklet attributable to errors in
transcription or printing and equally reserves the right to make any changes to the product it deems
useful and/or necessary without compromising its essential characteristics.

·

The manufacturer cannot be held liable for any damage caused by failure to comply with these

basic standards and all other use and maintenance standards contained in this booklet.

Summary of Contents for FMPG-20

Page 1: ...n and operating instructions PROFESSIONAL GAS PASTRY FRYER FPG 20 FPG 30 FMPG 20 FMPG 30 Model LIBR ISTR FPG Code 563010300 Review 1 Edition date 05 02 2020 Language English LOTUS S p A Via Calmaor 46...

Page 2: ...ections 7 4 BURNERS TECHNICAL DATA TABLE ITGB 11 4 1 Burners technical data table 11 5 INSTRUCTIONS FOR USE 12 5 1 General information 12 5 2 Switching the pilot burner on 12 5 3 Starting the main bur...

Page 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 FPG 20 30 A Data Plate C Gas connection...

Page 4: ...INTRODUCTION Translation of the original instructions 4 FIG 2 FMPG 20 30 A Data Plate C Gas connection...

Page 5: ...electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be hel...

Page 6: ...ginal instructions 6 2 2 Technical data table Technical data table FPG MODEL DIMENSIONS GAS FITTING ISO 7 1 RATED TOTAL GAS FLOW kW FPG 20 60x70x25h R GM 11 2 FPG 30 80x70x25h R GM 16 5 FMPG 20 60x70x...

Page 7: ...nstall the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulating m...

Page 8: ...t do not cause corrosion such as solutions of soapy water or leak detectors All our appliances are subjected to detailed examination the type of gas pressure in use and the pertinent category are indi...

Page 9: ...ned in a bag included in the supply and are marked in hundredths of mm see Burners technical data table INSTRUCTIONS FOR EVACUATING EXHAUST GASES A type devices see data plate A type appliances must d...

Page 10: ...iance must be possible only by hand If the installation is under a hood the terminal part of the appliance s exhaust pipe must be at least 1 8 meters from the appliance s support surface ground The ou...

Page 11: ...h KG G31 PROPANE 37 mbar 9 45 kWh m3st G20 METHANE H 20 mbar FPG 20 FMPG 20 Burner 11 2 kW Burner injector 1 100 mm 3 x 100 3 x 100 3 x 150 Pilot injector 30 30 51 Consumption kg h 0 875 kg h 0 875 m3...

Page 12: ...witching off the appliance wait for a sufficient time for it to cool before carrying out any cleaning or maintenance operation Fill the tank with oil up to the lower reference mark 5 2 Switching the p...

Page 13: ...than oil lard for example that have considerable thermal inertia it is necessary to set the thermostat to a low value e g 110 C during the first cycle not starting cold The thermostat can be set to t...

Page 14: ...uired to have a suitable recipient for emptying the water oil Insert the drain tube as shown on the drawing position the container Push the safety device upwards against the involuntary openings A and...

Page 15: ...ted on the component itself The appliance does not require any special maintenance but during the use of the equipment it is advisable to check the following at least once a year possibly increasing t...

Page 16: ...le with the appropriate version and make sure that after ignition the flame correctly touches the tip of the thermocouple Warning After conversion to another type of gas update the technical data plat...

Page 17: ...are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For m...

Reviews: