MAINTENANCE
Translation of the original instructions
19
·
Replace the nozzle with the appropriate version and make sure that, after ignition, the flame correctly
touches the tip of the thermocouple
Warning
After conversion to another type of gas, update the technical data plate to indicate the type of
gas for which the appliance has been converted.
6.4
Spare parts
It is possible to replace parts such as the valve, the piezoelectric or the ignition control unit (depending on
the type of appliance) or the gas pipes easily and quickly.
To replace such parts, proceed as follows:
·
VALVE (fig.B pos.9); the F45 fryer is fitted with a NOVA gas valve and a single-phase adjustment
thermostat. After dismantling the dashboard and/or front panel, unscrew the gas pipe screw couplings
and disconnect the valve's electrical connections.
·
THERMOCOUPLE (fig.D pos.3); unscrew the pilot burner coupling, unscrew the valve coupling in the
same way and replace the element
·
IGNITION SPARK PLUG (fig.D pos.4); unscrew the coupling, remove and replace the damaged part.
Caution
WHAT TO DO IN THE EVENT OF FAULTS:
Close the gas connection cock and/or switch off the power using the up-line device. Notify
customer service.
Warning
MEASURES TO BE TAKEN IF THE APPLIANCE IS NOT TO BE USED FOR A LONG TIME:
Close the gas cock and/or disconnect the power supply. Clean the system as specified above.