INSTRUCTIONS FOR USE

Translation of the original instructions

14

4 INSTRUCTIONS FOR USE

4.1

General information

This appliance must only be used for its expressly intended purpose for cooking or heating food. Any other
use is considered improper. The appliance is also intended for industrial use and must only be used by
personnel trained for use and aware of the risks that the hot element entails.
 

Warning

 

The appliance operates at high temperatures, so the following is necessary:

·

Pay attention to the areas surrounding the hot surface during routine normal operation

(danger of scalding);

·

RISK OF BURNS Do not touch hot surfaces floor with your hands or other parts of the body

to avoid burns caused by high temperatures;

·

After switching off the appliance, wait for a sufficient time for it to cool before carrying out

any cleaning or maintenance operation.

·

Fill the tank with oil up to the lower reference mark

 

4.2

Turning the appliance on/off

 

·

Turn on the switch located upstream of the appliance. Turn the knob from "0" to the desired position

between 110° and 190°C, the white and green indicator lights will turn on

·

The green indicator light indicates that the appliance is powered. The white indicator light indicates that

the heating element is functioning and when it turns off, this means that the temperature has been
reached

·

Turn the knob to “0” to switch off the appliance

 

4.3

Safety thermostat

The appliance is equipped with a safety thermostat which interrupts the gas flow if the temperature of the oil
bath exceeds the pre-set maximum value (230 °C). Safety intervention is signalled by the main burner and
the pilot burner both switching off. If this happens, operations can be reset by fully pressing the red button on
the safety thermostat. If the problem occurs again, call the assistance service so that the causes can be
eliminated.
 

Warning

Summary of Contents for F13-74ET

Page 1: ...CTRIC FRYERS FOR PROFESSIONAL USE F13 74ET F2 13 78ET F18 74ET F2 18 78ET F13T 74ET F2 13T 78ET F2 8 74ET F2 8T 74ET Model LIBR ISTR F70E POT Code 563005703 Review 1 Edition date 30 01 2019 Language E...

Page 2: ...electrical and electronic equipment 10 2 3 Technical data table 10 3 INSTALLATION 12 3 1 Delivery checks 12 3 2 Removing the packaging 12 3 3 Mechanical installation 12 3 4 Electrical gas connections...

Page 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 F 7 E FIG 2 F T 7 E A Data Plate B Electrical connection...

Page 4: ...INTRODUCTION Translation of the original instructions 4 1 2 Components FIG B ROTARY RESISTANCE 1 O rings 2 Rotary heating element...

Page 5: ...5 WIRING DIAGRAM C 1 Switch 2 Microswitch 3 Power supply terminal board 4 Power switching terminal block 5 Resistor switching terminal block 6 Heating element 7 White indicator light 8 Green indicator...

Page 6: ...lation of the original instructions 6 WIRING DIAGRAM D 1 Switch 2 Microswitch 3 Power supply terminal board 4 Heating element 5 White indicator light 6 Green indicator light 7 Contactor 8 Thermostat 9...

Page 7: ...lation of the original instructions 7 Wiring diagram reference table MODELS TERMINAL BOARD 1 TERMINAL BOARD 2 F13 74ET C F13T 74ET C F2 13 78ET C C F2 13T 78ET C C F18 74ET D F2 18 78ET D D F2 8 74ET...

Page 8: ...INTRODUCTION Translation of the original instructions 8 1 3 Example installation of the appliance...

Page 9: ...electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be hel...

Page 10: ...lection The penalties provided for in the event of improper disposal of RAEE Waste Electrical and Electronic Equipment are those provided for by the national transpositions of European Directives 2012...

Page 11: ...INFORMATION Translation of the original instructions 11 DESIGN ASSEMBLY TRANSFORMATION ELECTRICAL LINKING TERMINAL BLOCK PERNIONS see technical data table POWER SUPPLY CONNECTION HEATING ELEMENT CONN...

Page 12: ...not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulat...

Page 13: ...of it so that the device can be fully disconnected from the mains this device must have a contact aperture of at least 3 mm The connection terminal is located behind the rear wall Proceed as follows t...

Page 14: ...leaning or maintenance operation Fill the tank with oil up to the lower reference mark 4 2 Turning the appliance on off Turn on the switch located upstream of the appliance Turn the knob from 0 to the...

Page 15: ...at during the emptying stage the oil does not overflow and does not represent a hazard We recommend filtering the oil every day at the end of work and changing it when necessary Turn the oil drain coc...

Page 16: ...e and its safety systems Warning For maintenance replacement of components order and use only original spare parts Replacing parts must exclusively be performed by authorised and or qualified personne...

Page 17: ...g the heating element Unscrew the two 8 mm screws that fasten the bracket to the heating element and pull out the bracket until it can be removed At this point the heating element can be removed from...

Page 18: ...are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For m...