BURNERS TECHNICAL DATA TABLE (ITGB)
Translation of the original instructions
17
4 BURNERS TECHNICAL DATA TABLE (ITGB)
4.1
Burners technical data table
Technical data table - Burners PC CF S110G
12.68 kWh/KG
G30
BUTANE
30 mbar
12.87 kWh/KG
G31
PROPANE
37 mbar
9.45 kWh/m3st.
G20
METHANE H
20 mbar
Burner max 7 kW-min 1.8 kW
Burner injector 1/100 mm
130
130
195
Minimum adjustment 1/100 mm
65
65
adjustable
Pilot injector 1/100 mm
20
20
35
Consumption
kg/h 0.552
kg/h 0.544
m3 st./h 0.740
Primary air h = mm
open
open
1
Burner max 10 kW-min 2.3 kW
Burner injector 1/100 mm
155
155
230
Minimum adjustment 1/100 mm
75
75
adjustable
Pilot injector 1/100 mm
20
20
35
Consumption
kg/h 0.789
kg/h 0.777
m3 st./h 1.058
Primary air h = mm
open
open
1
Oven burner max 10 kW-min 3,5 kW
Burner injector 1/100 mm
155
155
245
Minimum adjustment 1/100 mm
100
100
adjustable
Pilot injector 1/100 mm
19
19
27
Consumption
kg/h 0,789
kg/h 0, 777
m3 st./h 1,058
Primary air h = mm
12
12
10