S35
Pre-Installation and Site Preparation Guide
1006705 Rev B
Loring Smart Roast Proprietary – This document is controlled by
Document Control. By printing this document, it will become a “Reference” copy.
Users are responsible for verifying that it is the latest revision available.
Page 11 of 52
S35 Specification
Value
Water Supply (Flow) Minimum
1 GPM (3.8 LPM) or greater
Water Pressure Minimum
50 psi (345 kPa) or greater
Compressed Air Flow, Minimum
4 CFM (0.11 m
3
min) or greater
Compressed Air Pressure, Minimum
80 psi (552 kPa) or greater
Natural Gas Pressure (Min/Max Range)
4 – 7 in WC (1.0 – 1.7 kPa)
Natural Gas Caloric Content, Minimum
1000 BTU/ft
3
(37 MJ/m
3
) or greater
Propane Gas Pressure (Min/Max Range)
11 – 13 in WC (2.7 – 3.2 kPa)
Propane Gas Caloric Content, Minimum
2500 BTU/ft
3
(93 MJ/m
3
) or greater
Requirements for Utilities
In order to ensure proper roaster performance, the customer should verify that the site utilities meet
basic requirements for water, compressed air, and gas. The customer must indicate whether the site
uses natural gas or propane.
Table 2.
S35 Utilities Requirements