G-Link
®
-LXRS
®
Wireless Accelerometer Node
User Manual
System Operational Overview
16
3.5
Channel Configuration
The sensor settings are stored in the node memory and each sensor is assigned a
corresponding channel number. Only the channels and configuration options that are
available on the type of node being used will appear in the configuration menus.
1. To enter the configuration menu, right-click on the node name, and select Configure >
Configure Node. The Channels tab displays channel options available for the node.
a.
Channel Enabled:
indicates the sensor channel number. The check box
is used to enable the channel and select it for sampling. The icon next to
the check box describes the channel type inherentto the node being used.
b.
Current channel configuration:
The Data Output, Units, Input Range,
and Label fields describe how the channel is currently configured.
c.
Configure:
Select the channel's Configure button to change the channel
parameters, such as measurement units, gain and offset settings, and
calibration values. The channel must be enabled first by selecting its
adjacent check box.
Figure 7 - Node Channels Menu