Starting up
- 38 -
01.21
909.2669.9-02
14
Starting up
14.1
Electrode welding process
Â
Select the electrode welding process with button 30 (LED
electrode- DC 33 or LED electrode- AC 34 lights up).
9
You are in the parameter main current I1 (LED Main current
I1 37 lights up).
Â
Use the rotary knob 41 to set the desired current intensity.
9
Your welding machine is now ready for use.
Electrode diameter
[mm]
Recommended current
intensity
[A]
1,5
20 - 40
2,0
35 - 60
2,5
45 - 100
3,2
75 - 140
4,0
130 - 190
5,0
180 - 260
Heed the electrode manufacturer’s instruc-
tions.
Parameter
Range
Factory
setting
LED
Main current I1
100
37
T 180
10 - 150 A
T 220 AC/DC
10 - 170 A
T 220 DC
10 - 180 A
T 250
10 - 200 A
T 300
10 - 200 A
Tab. 1:
Main parameters
The factory setting values are optimised thanks to automatic
parameters.
You can use these factory settings unchanged for most weld-
ing jobs.
Further fine adjustment facilities can be found in Chapter „14.3
Secondary parameters“ on page 39.
14.2
TIG welding process
Â
Select the TIG welding process with button 30 (LED TIG-
DC 31 or LED TIG- AC 32 lights up).
Â
Select the desired mode with button 47 (LED 2-stroke 44,
LED 4-stroke 45 or LED Pulse 46 lights up).
Â
48 Press the main parameter button on the bottom right
until the desired parameter appears (the corresponding
LED 35 - 43 lights up).
Â
Use knob 41 to set the desired value.
9
Your welding machine is now ready for use.
Electrode
diameter
[mm]
Recommended
current intensity
DC
[A]
Recommended
current intensity
AC
[A]
1,0
3 - 40
5 - 30*
1,6
15 - 130
20 - 90*
2,0
45 - 180
45 - 135*
2,4
70 - 240
70 - 180*
3,2
140 - 320
130 - 250*
4,0
220 - 450
200 - 320*
*) Depending on the type of electrode and AC-Balance param-
eter setting
Parameter
Range
Factory
setting
LED/
Code
Gas pre-flow time
0,1 - 10 sec.
0,1
35
Upslope
0 - 99 %
5
36
Main current I1
100
37
T 180
3 - 180 A
T 220
3 - 220 A
T 250
5 - 250 A
T 300
5 - 300 A
Second current I2
1 - 200 % of main
current
50
40
Pulse frequency (only for
pulse mode)
0,2 - 2000 Hz
(representation
0.2 - 2.0t)
5
39
Downslope
0 - 500 %
20
42
A synchronisation takes place in the DC pulse operating mode
with feed or control The current reduction always begins with I2
independent of the current status I1 or I2.
Gas post-flow time cor-
rection
20 - 500 %
100
43
Tab. 2:
Main parameters
The factory setting values are optimised thanks to automatic
parameters.
You can use these factory settings unchanged for most weld-
ing jobs.
Further fine adjustment facilities can be found in Chapter „14.3
Secondary parameters“ on page 39.
ii
Summary of Contents for T 180 AC BasicPlus
Page 11: ...Vor der Inbetriebnahme 11 01 21 909 2669 9 02 ...
Page 35: ...Before commissioning 35 01 21 909 2669 9 02 ...
Page 59: ...Antes de la puesta en marcha 59 01 21 909 2669 9 02 ...
Page 83: ...Voor de inbedrijfstelling 83 01 21 909 2669 9 02 ...
Page 107: ...Перед вводом в эксплуатацию 107 01 21 909 2669 9 02 ...
Page 131: ...Przed uruchomieniem 131 01 21 909 2669 9 02 ...
Page 155: ...Antes de colocar em funcionamento 155 01 21 909 2669 9 02 ...
Page 179: ...Avant la mise en service 179 01 21 909 2669 9 02 ...
Page 203: ...Před uvedením do provozu 203 01 21 909 2669 9 02 ...
Page 227: ...Prima di cominciare 227 01 21 909 2669 9 02 ...