code
designation
cause
remarks
H30-02
configuration calibration data
no valid calibration data could be found
Standard calibration data are used instead,
this can result in a difference between the dis
-
played current value and the real current value.
H30-03
configuration maximum
current
no valid data for the maximum current could be
found
Standard values are used instead, it can hap-
pen that the machine is not able to reach the
maximum current.
H30-04
configuration duty-cycle
no valid data for the duty cycle could be found
Standard values are used instead, it can hap-
pen, that the machine has a less duty cycle
than normal.
H31-07
Communication DMR
The internal CAN bus communication between
MAPRO and DMR-RT3 is blocked or interfered.
-check CAN bus wires between DMR-RT3
(X8) and DRV (X1)
-check CAN bus wires between DRV (X2) and
MAPRO (X7)
nFc-H01 Read/write error
Cancel, faulty saving
Present card again
nFc-H02 NFC card invalid
No valid Lorch NFC card
Use suitable NFC card
nFc-H03 Connection interrupted
Interruption on removing the NFC card
Present card again
nFc-H10 NFC card used
NFC card has already been used
-
nFc-H11 Incorrect serial number
Not intended for this welding device
Use a suitable NFC card
nFc-H12 NFC card blocked
Action was interrupted during installation on
another system
Complete the installation operation on the
other system
nFc-H13 Incorrect TAN code
Code input incorrectly, incorrect input values
on the TAN website. (e.g.: Swap: "b" and "6" or
missing ".")
Check the input on the TAN server Check the
TAN web address.
nFc-H15 Decryption error
Incorrect data, card not from Lorch
Use a suitable NFC card
nFc-H16 Invalid signature
Data error, no valid Lorch signature
Use a suitable NFC card
nFc-H30 Upgrade already installed
Update already performed
-
nFc-H31 Invalid customer number
Welding program created for another customer
Use a suitable NFC card
nFc-H32 Invalid product family
NFC card not suitable for this product family/
series
Use a suitable NFC card
nFc-H33 Authorisation required
Lorch authorisation card must be used first, or
time run out
Perform authorisation again
nFc-H34
Insufficient user level
e.g. action not available for WPS welder
Contact welding supervisor
nFc-H35 Condition failed
General conditions are not fulfilled
Are all preconditions fulfilled (card label/order
data). Have the card checked
nFc-H40 Activation error
Data error on the card or function not supported Have the card checked
nFc-H41 Inconsistent data
Data error on the card
Have the card checked
nFc-H46
Wrong job card contents
Job card does not fit to compensation mode
Re-write job card or change the compensation
mode to “cable length”
nFc-H59 Missing NFC-card informa-
tion or decryption error
Incompatible front panel firmware
Make software update to power source and
front panel (with LSM)
nFc-H61 NFC card invalid
Invalid card type
nFc-H62 NFC card invalid
Wrong card type for this TAN process
request a new card
nFc-H63 Incompatible front panel for
this process
Incompatible front panel firmware
Make software update to power source and
front panel (with LSM)
nFc-H64 Inconsistent data
Data error on card
Let card check by Lorch
noP-H20 Function upgrade missing
e.g. read NFC not updated
Perform the necessary upgrade first
noP-H21 Material upgrade missing
e.g. CrNi job loaded to device but device with-
out CrNi upgrade
noP-H22 Process upgrade missing
e.g. SpeedArc job loaded to device but device
without SpeedArc upgrade
noP-H23
Welding program missing
Job with welding program number not available
on device
noP-H24 Incorrect software
Incompatible software version
SW update (Master, control panel)