page 55
Machine Configuration
The hardware configuration is saved internally inside the machine. When switching on, the MAPRO is reading the
configuration and compares it with the actual present hardware identifications of the DRV, the actual software ver
-
sion and the identification of the front panel.
If the configuration does not match the actual hardware configuration or if the configuration could not be read cor
-
rectly, the machines stops with
E30
“Configuration”.
code designation
cause
E30-04
configuration primary
the measured bus voltages do not match the actual saved configuration
E30-05
error configuration
error when reading the configuration: no valid data present or data is corrupted
E30-06
configuration software the actual software does not fit to the hardware
R25 R26 R27
configuration
DIP1 DIP2
configuration
X
X
300 / 350
OFF
OFF
3-phase 400V
X
400
OFF
ON
3-phase 230V
X
X
500
ON
OFF
multivolt (selection switch 230V / 400V)
Configuration resistors DRV13
DRV15
R25
R26
R27
DIP
DIP
R25
R26
R27
Configuration resistors DRV17
R25
R26
R27
DIP