Please refer to the following table for LED definition 

Type

LED

Status

Operation

Steady Green 

Power is on 

Power

Off

Power is off

Steady Green 

Power on diagnostics testing

Off

Power on diagnostics test successful

System

Status

Blinking Green 

Power on diagnostics test fail 

Steady Green 

Connected as 100Mbps 

100M

Off

Connected as 10Mbps 

Steady Green 

The port is linking up 

Blinking Green 

There is traffic transverses the port

Port 1~24 
(10/100Mbps)

LINK/ACT

Off

No connection

Steady Green 

Linking up / Current connecting speed 

SPEED (10M, 
100M, 1000M)

Off

All off for Linking down 

Steady Green 

There is traffic transverses the port

TX; RX 

Off

No connection

Steady Amber

Full Duplex mode 

Off

Half Duplex mode 

Port 25, 26 
(10/100/1000Mbps)

FDX/COL

Blinking Amber 

Collision

You could use a normal RS-232 cable and connect to the console port on the device. After the 

connection, you could run any terminal emulation program (Hyper Terminal, Winterm, Telix, … and 

so on) to enter the startup screen of the device. For all the detail software operation, please refer 

to “Console Program” session. 

…

DCE

…

9600 (Fix baud rate) 

…

8 (8 Data bits) 

…

n (No parity checking) 

…

1 (1 stop bit) 

…

None (No flow control)

2

LED Definition

Console Port

Summary of Contents for LCS-883R-SW2402

Page 1: ...to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CE M...

Page 2: ...res Store and forward switching mode promises the low latency plus eliminates all the network errors including runt and CRC error packets To work under full duplex mode transmission and reception of t...

Page 3: ...up Current connecting speed SPEED 10M 100M 1000M Off All off for Linking down Steady Green There is traffic transverses the port TX RX Off No connection Steady Amber Full Duplex mode Off Half Duplex m...

Page 4: ...Station Connection Connect each station to the switch by a category 5 twisted pair cable straight or cross over cable Plug one RJ 45 connector into a front panel port of the switch and plug the other...

Page 5: ...operating status of all ports and setup the port configuration like Speed Duplex mode Bandwidth Control and Flow Control VLAN Configuration Supports up to 26 groups Port Based 802 1Q VLAN Ports Trunk...

Page 6: ...Move the cursor to port 5 Speed Duplex setting column by pressing Tab 2 Press Space bar to select 10Half mode 3 Press Tab to Bandwidth setting column 4 Press Space bar to select 60 5 Press Tab to Flo...

Page 7: ...ol key Ctrl O can quickly divide all ports into separate subnets but port 24 is reserved for up linking to another device and belongs to every Port Based VLAN in advance unless you manually change it...

Page 8: ...cket will be added into VLAN tag 10 automatically according to PVID table Then this packet will be forwarded to VID 10 group But if the VLAN group with VID 10 not exists this packet will be dropped Po...

Page 9: ...uration The 24 2 Gigabit Smart Switch provides Ports Mirroring Configuration to snoop a specified port Setup a Monitored port the packets will be duplicated to the Monitoring port Miscellaneous This M...

Page 10: ...e Save Current Configurations The settings that you have applied are all saved in the volatile memory Every time when switch reboots system obtains system parameters you saved before in non volatile m...

Page 11: ...10 Network Application...

Page 12: ...Rate 10 100 1000Mbps Transmission Mode 10Mbps Full Half Duplex 100Mbps Full Half Duplex 1000Mbps Full Duplex LED indications System Power Status Port 100M LINK ACT 10M 100M 1000M TX RX FDX COL System...

Page 13: ...s In Conformity With Standards Results EN 55022 1994 A1 1995 A2 1997 Class A Pass EN 61000 3 2 1995 A1 1998 A2 1998 Class A Pass EN 61000 3 3 1995 Pass EN 55024 1998 Pass IEC 61000 4 2 1995 Pass IEC 6...

Page 14: ...13 Date 18 09 2002...

Reviews: