Operating Instructions
Learn Setup
The product Learn parameters for optimum detector performance are automatically selected during a
Full Learn process so no manual adjustment of the parameters is normally required.
If adjustments are required then you should contact your local Loma Service Centre in the first
instance.
To manually adjust the product Learn parameters, proceed as follows:
1.
Select
Menus > Learn > Set Up
to display the
Set Up
menu options which are listed and
described below.
2.
Use the
Navigation Keys
to select each option in turn and press the
OK /
Enter Key
to enable the value to be edited.
3.
Use the
Navigation Keys
to select the required option value and then
press the
OK / Enter Key
to confirm the selection.
4.
Repeat step 2 and 3 until you have selected and confirmed values for each option.
The Set Up menu options available are as follows:
■
Auto-Frequency
If this option is enabled, the operating frequency to be used by the detector for the product
being Learnt is automatically selected.
If the option is not enabled then the Frequency to be used can be manually selected in the
Frequency option.
■
Frequency
The operating frequency for the detector, assigned to a product memory, is displayed or can
be selected when operating manually.
■
Working mode
The level of transmitter power is selected here by selecting options of P-Mode, Q-Mode or
Dry.
The mode is automatically selected during a Full Learn process but may be manually set if
required. For products with no electrical conductivity the Dry option should be selected
■
Working
Enabling this option locks the Working mode setting, thus preventing the detector from
changing it during a Full Learn process.
■
Min threshold
The value entered here sets the lowest threshold that the detector can set during any Learn
process.
■
Max threshold
The value entered here sets a level that during any Learn process if exceeded will abort the
process. Its purpose is to prevent a successful Learn being achieved for a contaminated
sample product.
■
Detection Threshold
This is the detectors working threshold, set automatically after a completed Learn process. It
may be manually set here if required.
98
Summary of Contents for IQ3
Page 2: ......
Page 10: ......
Page 26: ......
Page 43: ...Installation 33 ...
Page 60: ...Installation THIS PAGE IS INTENTIONALLY LEFT BLANK 50 ...
Page 70: ...About the Metal Detector Range THIS PAGE IS INTENTIONALLY LEFT BLANK 60 ...
Page 74: ...Getting Started IQ3 Dual Line Display Menu Map 64 ...
Page 116: ...Operating Instructions THIS PAGE IS INTENTIONALLY LEFT BLANK 106 ...
Page 140: ...Maintenance THIS PAGE IS INTENTIONALLY LEFT BLANK 130 ...