background image

www.logtagrecorders.com

UTREL30-WiFi

Wireless Low-

Temperature Data Logger

 
 

Product User Guide

LogTag Recorders

 

Document Release Version: 1.0

Published 21. December 2020

Copyright © LogTag Recorders, 2004-2020

Summary of Contents for UTREL30-WiFi

Page 1: ...ww logtagrecorders com UTREL30 WiFi Wireless Low Temperature Data Logger Product User Guide LogTag Recorders Document Release Version 1 0 Published 21 December 2020 Copyright LogTag Recorders 2004 202...

Page 2: ...TREL30 WiFi for first use 14 In the office 14 On site 14 Inserting the Batteries 15 Configuring the UTREL30 WiFi for logging 16 Finalizing the configuration 25 LogTag Online Connection Wizard 26 Addin...

Page 3: ...ction mark 52 Clearing an Alarm 52 Paused Readings 54 Probe is disconnected 54 Power Save 55 Clearing the Min Max Values 56 Reviewing Day Statistics on the Display 57 Stopping the UTREL30 WiFi 62 Auto...

Page 4: ...User Guide 4 Resetting the Logger 72 Hibernating a UTREL30 WiFi 73 Airplane Mode 74 Replacing the Batteries 74 Technical Specifications 75 Temperature Accuracy 77 Temperature Resolution 77 Appendix 1...

Page 5: ...ad to the destruction of the battery and may cause injuries Empty batteries should be recycled or disposed of according to your local regulations Liability LogTag Recorders standard warranty terms app...

Page 6: ...formation Regulatory Compliance This module has been tested and complies with the FCC IC RSS 210 CE and SRRC rules and regulations for intentional transmitters Any limits in these regulations typicall...

Page 7: ...Text in this font describes features of the product This text describes certain aspects of the product where incorrect use of a feature may lead to inadvertent loss of data This text contains importa...

Page 8: ...rent time and battery status l an alarm trigger summary of up to the last 30 days today and 29 days previous and l the wireless and cloud connection states At set intervals the UTREL30 WiFi uploads th...

Page 9: ...ng of logger to fixtures l Micro USB socket with attached protective cap l Gold plated high quality temperature sensor socket l Robust polycarbonate case IP51 l 2 user replaceable AAA backup batteries...

Page 10: ...ccurred External Probes The UTREL30 WiFi will accept any external probe from the ST10 product range Communication The UTREL30 WiFi offers two means of downloading data 1 Use the built in Micro USB soc...

Page 11: ...Features UTREL30 WiFi User Guide 11 and also includes a day summary page showing an overview of the statistics collected A CSV file of the data list is also available...

Page 12: ...computer s USB socket l An external probe of the ST10 series l A PC running Windows 7 SP1 or later and LogTag Analyzer 3 installed or a stand alone version of the LogTag Online Connection Wizard l A P...

Page 13: ...What You Need UTREL30 WiFi User Guide 13 l A silica sand temperature buffer which simulates environmental behavior of a vaccine vial...

Page 14: ...using LogTag Analyzer software 4 Connect the UTREL30 WiFi to your wireless network using the LogTag Online Connection Wizard 5 Complete the device setup in LogTag Online including associating the UTR...

Page 15: ...th two AAA batteries 1 Remove the screw from the rear compartment lid 2 Remove the lid exposing the battery compartment 3 Insert the AAA batteries in the correct orientation as shown The polarity is m...

Page 16: ...mber of different profiles that are available Also your reseller may have already configured the device to be connected to your wireless network You can check if your logger is already configured or n...

Page 17: ...ms This is done using LogTag Analyzer software which can also be used for downloading and analyzing data LogTag Analyzer includes the LogTag Online Connection Wizard which will allow you to set wirele...

Page 18: ...n Wizard 2 Register the device in LogTag Online 3 Attach the UTREL30 WiFi to a location During the attachment process select one of the pre defined Logger Configuration Profiles Each profile contains...

Page 19: ...other LogTag logger products and includes settings such as User ID start method pre start recording logging interval and duration start delay and password Adjust the settings as required For detailed...

Page 20: ...uploaded to LogTag Online Using pre start readings is a good way to avoid data loss if you forget to start the unit as you can still access the data using LogTag Analyzer Start delay If you configure...

Page 21: ...upper threshold temperature it is called an upper alarm If an alarm trigger condition requires readings to go below a lower threshold it is called a lower alarm All alarm trigger conditions are confi...

Page 22: ...ow the previous day When midnight passes next this marker will move to and so on Alarm Re triggering A note on alarm re triggering As soon as an alarm is triggered the corresponding delay time but not...

Page 23: ...wn on the display l Date and time format l Time zone and MKT values Following specifically influences the appearance of the PDF file l Scaling parameters for the chart l Showing or hiding grid lines l...

Page 24: ...wing parameters influence specific behavior of the UTREL30 WiFi l Clearing and resetting alarms when the START CLEAR STOP button is pressed l Leaving the alarm turned on even if readings return to the...

Page 25: ...advise your network administrator of the MAC address shown in this screen so it is allowed to connect to the network Factory new units do not contain any settings In this case please use the LogTag O...

Page 26: ...gTag Online Connection Wizard starts after the logger has been configured for other parameters such as logging and alarms When the wizard runs the wireless and network parameters you enter are used to...

Page 27: ...can fail The UTREL30 WiFi is now ready to be deployed Adding the Probe and the Power Supply Before the UTREL30 WiFi can record temperature data you will need to connect an external probe The UTREL30...

Page 28: ...automatically register the UTREL30 WiFi for you if you provide your sign in details when you run the Wizard You can also register the device by signing in to your LogTag Online account at https logta...

Page 29: ...ings to the cloud server every 15 minutes If a logger is scheduled to take a temperature reading and also upload readings to the server at the same time the temperature reading will always be taken fi...

Page 30: ...o the WLAN to preserve battery power Instead the connection is re established automatically at the next scheduled data upload to the LogTag Online cloud server This symbol shows the status of the last...

Page 31: ...s identity l request any information from the server such as the current time l upload any new temperature and event data that have been recorded since the last connection to the cloud server l close...

Page 32: ...0 WiFi has successfully established a connection to the LogTag Online cloud server Cloud symbol shows a tick The UTREL30 WiFi is now exchanging data with LogTag Online indicated by an arrow inside the...

Page 33: ...lease refer to the section about Troubleshooting on the next page for further details This connection test is performed automatically every time the UTREL30 WiFi takes the first reading of a new trip...

Page 34: ...the wireless and network indicators to help narrow down which part of the upload process fails The UTREL30 WiFi is trying to access the wireless network but has not yet successfully connected If you...

Page 35: ...vice l The network has an unsupported authentication method At present the UTREL30 WiFi can only connect to wireless networks with WEP or WPA WPA2 access without enterprise functions Contact your dist...

Page 36: ...discuss this with your network administrator and run the LogTag Online Connection Wizard again selecting Advanced Setup l No IP address or DNS server configured Please re run the LogTag Online Connect...

Page 37: ...larm event occurred during that week MIN MAX Temperature Data These two temperatures represent the minimum and maximum since the recording started or since the values were last manually cleared Main T...

Page 38: ...gether with the time in hours and minutes until the start l If is shown the UTREL30 WiFi is recording temperature at the sample interval defined during configuration l If is shown together with the wo...

Page 39: ...temperature on the display represents the minimum recorded temperature for the day displayed MIN and MAX are also shown next to the minimum and maximum values during recording if these are enabled Abo...

Page 40: ...A batteries as a backup should external power be unavailable for example in the event of a power cut If used as a backup the batteries have a life span of approximately 6 to 12 months depending on the...

Page 41: ...Replacing only one of the batteries with a partially charged battery will drain the secondary backup battery Rechargeable AAA cells are not recommended for this product The different charge voltage me...

Page 42: ...rt however a recording in progress can be stopped and a scheduled date time start will proceed and l Min Max values cannot be cleared After pressing any button following is shown on the display l The...

Page 43: ...32 LiMnO2 coin cell should be replaced immediately when the low battery symbol as shown appears This can be done by a qualified technician Failing to replace the battery can result in loss of configur...

Page 44: ...for the first 24 hours then sound less frequently to preserve battery life5 until the alarm is cleared the unit stops or is re configured Note The interval will increase even if the alarm is re trigge...

Page 45: ...alyzer This prevents the data logging becoming discontinuous which would be the case if the real time clock were to be changed together with the display clock The UTREL30 WiFi s real time clock regula...

Page 46: ...n start After configuration for a push button start the current time and READY are shown together with the Backup Battery Status symbol The power symbol is shown when the unit is connected to a USB po...

Page 47: ...Push Button Start with Start Delay If the logger has been configured for a push button start with a start delay the word STARTING DELAY is shown instead of the symbol The delay time is shown in hours...

Page 48: ...on until STOPPED disappears Automatic date time start If you configured the UTREL30 WiFi for a date time start it will start recording temperature values as soon as the entered start time is reached U...

Page 49: ...alarm was recorded are highlighted The WiFi and cloud connection symbols are also shown Following are some sample display screens At 1 25 pm l Alarm events were recorded 6 18 19 27 days ago The follow...

Page 50: ...ange none of the alarm threshold markers are visible but the alarm remains present as it has not been inspected and cleared l The day summary has shifted by 1 day as the display time has passed throug...

Page 51: ...10 1 week and 3 days Day 11 1 week and 4 days Day 12 1 week and 5 days Day 13 1 week and 6 days Day 14 2 weeks Day 15 2 weeks and 1 day Day 16 2 weeks and 2 days Day 17 2 weeks and 3 days Day 18 2 we...

Page 52: ...n AM or PM inspection depending on the time of day the inspection took place Clearing an Alarm During configuration with LogTag Analyzer you can allow users to clear an alarm on the display This is a...

Page 53: ...ill show an AM or PM inspection depending on the time of day the alarm was cleared Note Only the Alarm Indicator can be cleared The day alarm marker in the above example remains shown as it is part of...

Page 54: ...he display shows PAUSED next to the symbol PAUSED will turn off as soon as the last ignored reading has been recorded The option is set in the Advanced Settings tab during configuration with LogTag An...

Page 55: ...d back in If the probe was disconnected for a complete day the minimum and maximum statistics for that day will show on the display and in the list Power Save When Power Save is enabled the display wi...

Page 56: ...e dashes remain on screen The values will not be reset and the currently stored min max values will be retained if l you keep holding the button for more than 2 seconds after the dashes no longer blin...

Page 57: ...ions on page 21 Today s data Pressing the button displays the current day s maximum statistic l The Today marker flashes to indicate that today s data is being displayed l Today no temperature values...

Page 58: ...the threshold l The maximum temperature recorded yesterday was 57 3 C Pressing the button now displays yesterday s minimum statistic l flashes as we are still looking at yesterday s data l Yesterday n...

Page 59: ...elow the lower alarm threshold and no alarm event was generated l The minimum temperature recorded on the day before yesterday was 74 8 C Data from 6 days ago After pressing the button for a few times...

Page 60: ...bove the upper threshold were recorded indicated by the upper alarm threshold marker l The duration was 5 hours 20 minutes l An alarm event was generated indicated by the symbol Neither duration from...

Page 61: ...9 1 week and 2 days Day 10 1 week and 3 days Day 11 1 week and 4 days Day 12 1 week and 5 days Day 13 1 week and 6 days Day 14 2 weeks Day 15 2 weeks and 1 day Day 16 2 weeks and 2 days Day 17 2 week...

Page 62: ...on about this option Manually You can configure a UTREL30 WiFi so it can be stopped with the START CLEAR STOP button This feature is useful when you take the logger out of a shipment and don t want to...

Page 63: ...Online to upload any outstanding temperature readings Once the logger has stopped the last alarm status before the logger stopped will continue to be indicated with a cross or a tick symbol on the dis...

Page 64: ...rivers will not be installed if the UTREL30 WiFi does not generate files l USB Input Device HID Driver This device is used for communication to LogTag Analyzer and its driver will always be installed...

Page 65: ...d from the serial number of the UTREL30 WiFi You can access the files by browsing to the newly created drive and double clicking the PDF CSV or LTD files l For PDF files you need Adobe Acrobat Reader...

Page 66: ...Report with multiple alarms Alarm Status This shows at a glance if the UTREL30 WiFi recorded alarm conditions during the trip showing a red or if no alarms were recorded showing a green Recorded Data...

Page 67: ...nally see a gap in the graph where the UTREL30 WiFi would otherwise have taken a reading The list shows instead of the reading Recorded Data Chart The chart shows a graphical representation of the dat...

Page 68: ...Upper Threshold Lines Upper alarm thresholds are shown with red dashed lines so you can see at a glance where temperatures went above set limits You may see up to three lines depending on configurati...

Page 69: ...a List File Information The information from the report page is repeated here Recorded Data list The Data list shows a single row for each recorded reading along with the date time and temperature val...

Page 70: ...own when the Paused feature was enabled and any button was pressed during recording l A symbol will be shown where a reading could not be taken due to USB communication with a PC l A symbol will be sh...

Page 71: ...row contains the following information l Minimum and maximum for the day l Whether or not an alarm was recorded for that day l If the minimum and maximum temperatures were above or below the threshold...

Page 72: ...tings are retained For this process to work the logger must be STOPPED Press and hold the START CLEAR STOP button The READY symbol will turn on When the STOPPED symbol turns off release the button wit...

Page 73: ...gTag Analyzer by clicking Hibernate from the LogTag menu Initially the display shows SLP on the display until you remove the logger from the USB port A hibernated logger has no active display however...

Page 74: ...off After removal of the logger from the aircraft airplane mode can be turned off using the exact same procedure l Press and hold the FN and START CLEAR STOP buttons simultaneously l Keep holding the...

Page 75: ...eal time clock rated accuracy 25ppm 25 C equiv to 2 5 seconds day Rated temperature coefficient is 0 034 0 006ppm C i e typically 0 00294seconds day C Recording Capacity 16 129 real time temperature v...

Page 76: ...from AAA batteries or external power1 Size 141 mm H x 72 mm W x 18 mm T Weight without probe 134 g without batteries approx 158 g with 2 x AAA batteries Calibration Factory calibration using instrume...

Page 77: ...lowing graph shows the typical rated temperature accuracy of a UTREL30 WiFi Figure 4 Rated Temperature Accuracy Chart Temperature Resolution The following graph shows the typical rated native temperat...

Page 78: ...cumulative alarms and defines the number of recorded values that need to be alarm readings for the trigger condition to be met Alarm Event Single occurrence of an alarm Alarm Range Temperature humidit...

Page 79: ...r alarm I Inspection Pressing the Mark button on a logging device Inspection Event Pressing the Mark button on a logging device Instant Alarm One single temperature or humidity reading is above or bel...

Page 80: ...range Single Event Alarm Temperature or Humidity readings are above or below the configured threshold for the time defined without interruption T Tertiary Alarm The alarm threshold third closest to t...

Reviews: