background image

UTRED30-WiFi

Wireless 

Temperature 

Data Logger

 
 

Product User 

Guide

 

Document Release Version: 1.3

Published 22. May 2019

Copyright © LogTag Recorders, 2004-2019

LogTag Recorders

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for UTRED30-16-WiFi

Page 1: ...rature Data Logger Product User Guide Document Release Version 1 3 Published 22 May 2019 Copyright LogTag Recorders 2004 2019 LogTag Recorders www GlobalTestSupply com Find Quality Products Online at...

Page 2: ...LogTag Online 17 Wireless and Cloud Symbols 18 Testing your wireless and network connection 19 Troubleshooting 21 Display Overview 23 Powering the UTRED30 WiFi 25 Low power operation 26 Audible Alarm...

Page 3: ...tion Report 43 Data Evaluation Data List 45 Data Evaluation Day Summary 47 Resetting the Logger 48 Hibernating a UTRED30 WiFi 48 Airplane Mode 50 Replacing the Batteries 50 Technical Specifications 51...

Page 4: ...of the monitored goods if any l For incorrect readings if the device was used with a low battery l For consequential loss Battery Life The batteries in the UTRED30 WiFi are designed to power the devi...

Page 5: ...previous the wireless and cloud connection states At set intervals the UTRED30 WiFi uploads these data to your LogTag Online cloud account where they can be viewed analyzed and shared with others or d...

Page 6: ...statistics history on the logger s display or in more detail via your LogTag Online cloud account In addition a red Alarm LED shows if an alarm event has occurred Sensors The UTRED30 WiFi will accept...

Page 7: ...ion a PC running Windows 7 or later and LogTag Analyzer version 3 installed l a 5V 5W USB power supply to power the unit permanently via the USB socket Optional Items In addition to the above followin...

Page 8: ...g Analyzer l connect the UTRED30 WiFi to your wireless network using the LogTag Online Connection Wizard l complete the device setup in LogTag Online including associating the UTRED30 WiFi with a loca...

Page 9: ...from the rear compartment lid 2 Remove the lid exposing the battery compartment 3 Insert the AAA batteries in the correct orientation as shown The polarity is marked inside the battery compartment 4...

Page 10: ...the other end of the cable into a USB socket on your computer and wait for the drivers to be installed1 l Slot the logger into the interface contacts facing down and towards the rear of the interface...

Page 11: ...mperature readings at the date and time you specify local time You cannot combine a date time start with pre start readings or the start delay function Alarm Configuration Options The UTRED30 WiFi can...

Page 12: ...he corresponding delay time but not any others resets to zero and alarm processing starts again The alarm processing for all other alarm delays is not affected Therefore accumulative or consecutive al...

Page 13: ...ng alarm threshold lines l creation of the data list For detailed information about each parameter please read the section about Configuring a LogTag for logging in LogTag Analyzer s User Guide or pre...

Page 14: ...user to reset the logger with the START CLEAR STOP button l Enabling the buzzer for the audible alarm For detailed information about each parameter please read the section about Configuring a LogTag f...

Page 15: ...sters the UTRED30 WiFi against your account l enables you to create an account with LogTag Online or sign in if you already have an account l allows configuration of wireless and network parameters of...

Page 16: ...ready to be deployed Adding the Sensor and the Power Supply Before the UTRED30 WiFi can record temperature data you will need to connect an external sensor The UTRED30 WiFi accepts any ST100 sensor P...

Page 17: ...the data can be stored In LogTag Online this is called a location and associating the logger with this location is called attaching the logger Unlike other loggers uploaded via one of the wireless in...

Page 18: ...ection to the wireless network WLAN If the circle shows a tick the UTRED30 WiFi s last connection to the wireless network was successful When USB power is supplied the UTRED30 WiFi remains connected t...

Page 19: ...ion to the cloud server l close the connection This will give you immediate feedback if the logger s wireless and network settings were configured correctly To initiate the connection test press and h...

Page 20: ...ain to indicate that the last connection was successful The Devices page in LogTag Online will be updated with the last connection time If the wireless or cloud communication fail WLAN or Cloud symbol...

Page 21: ...tempted to connect to the wireless network but was unsuccessful It will take up to 60 seconds for this icon to show l the configured network is temporarily unavailable or out of range Try to scan for...

Page 22: ...of different reasons which include the following l No DHCP server found on the network You may have set up the UTRED30 WiFi to use DHCP but your network does not offer DHCP connections Please discuss...

Page 23: ...e UTRED30 WiFi is recording Once the logger has stopped nothing will be displayed Backup Battery Low A battery test is performed every 24 hours The battery low symbol will appear if the UTRED30 WiFi s...

Page 24: ...identify which of those is displayed l If the word TIME is shown the time value represents the current time in hours and minutes 24 hour format l If the word DELAY is shown the time value represents...

Page 25: ...l USB power Running the UTRED30 WiFi solely without an external supply is possible but not recommended as it will deplete the AAA batteries in around 2 to 3 months and also shorten the life of the sec...

Page 26: ...ay o The Recording state indicators show if the unit is recording stopped ready or configured for a delayed start o The Backup Battery Empty symbol is shown The internal secondary backup battery will...

Page 27: ...ering alarms in Alarm Re triggering on page 12 The buzzer will temporarily turn off when you are reviewing data and in Low Power mode Real Time Clock The time shown on the recording display is linked...

Page 28: ...ton start the current time and READY are shown together with the Backup Battery Status symbol The power symbol is shown when the unit is connected to a USB power supply WiFi and cloud connection symbo...

Page 29: ...The WiFi connection symbol is shown with a tick if the UTRED30 WiFi successfully connected to the wireless network directly after configuration with LogTag Analyzer As with a regular push button star...

Page 30: ...time is reached the logger shows the normal recording display The UTRED30 WiFi will perform a Connection Test as soon as the recording has started To check the connection before the start time is reac...

Page 31: ...ture has remained above the upper alarm threshold and has now triggered an alarm event l The alarm symbol is shown to indicate an alarm event occurred l The day marker for the current day is shown l T...

Page 32: ...days Day 12 1 week and 5 days Day 13 1 week and 6 days Day 14 2 weeks Day 15 2 weeks and 1 day Day 16 2 weeks and 2 days Day 17 2 weeks and 3 days Day 18 2 weeks and 4 days Day 19 2 weeks and 5 days D...

Page 33: ...ART CLEAR STOP button After approx 2 seconds the cross will be replaced with the tick Release the button when the tick appears The normal recording display is shown The alarm will not be cleared if yo...

Page 34: ...will show longer if the button is pressed just after the logger takes a reading but shorter if you press the button just before For example if you configure a logging interval of 10 minutes and 2 pau...

Page 35: ...e last recorded temperature These values can be reset any time while the unit is recording but not once the unit has been stopped To reset the values follow this procedure l Press and hold the REVIEW...

Page 36: ...rded today was 4 8 C l The paused function is enabled Pressing the button again displays the current day s minimum statistic l still flashes as the same day s data today are being displayed l Today no...

Page 37: ...iod so no alarm event was generated l The maximum temperature recorded on the day before yesterday was 11 5 C Pressing the button now displays the minimum statistic from two days ago l flashes as we a...

Page 38: ...recorded indicated by the upper alarm threshold marker l The duration was 5 hour 30 minutes l An alarm event was generated Neither duration from day 6 nor 7 by itself would cause an alarm event howev...

Page 39: ...asy Day 11 1 week and 4 days Day 12 1 week and 5 days Day 13 1 week and 6 days Day 14 2 weeks Day 15 2 weeks and 1 day Day 16 2 weeks and 2 days Day 17 2 weeks and 3 days Day 18 2 weeks and 4 days Day...

Page 40: ...ith readings taken after the shipment completion The stop function is enabled in the Advanced Settings tab during configuration When enabled following will stop the unit Press and hold the START CLEAR...

Page 41: ...o devices are required so you can access the data files in the same way as a USB memory stick These drivers will not be installed if the UTRED30 WiFi does not generate files 3 USB Input Device HID Dri...

Page 42: ...e newly created drive and double clicking the PDF CSV or LTD files For PDF files you need Adobe Acrobat Reader or a similar PDF viewer To open the LTD file you need to install the free LogTag Analyzer...

Page 43: ...d time formats and the file name which is compiled from information about the data it contains LogTag_ serial_number _ trip number _ file creation date _file creation time _ OK or ALM pdf Logger Infor...

Page 44: ...TRED30 WiFi has been downloaded or where an inspection mark has been placed with the START CLEAR STOP or REVIEW MARK button It also shows Paused marks where a button press has prevented readings from...

Page 45: ...from the report page is repeated here Recorded Data list The Data list shows a single row for each recorded reading showing the date time and temperature values plus any special events that were recor...

Page 46: ...adings were paused as a result of a button press if the Paused function was enabled The logger was communicating via USB and could not take a reading at the required time The min max readings were res...

Page 47: ...maximum for the day l whether or not an alarm was recorded for that day l if the minimum and maximum temperatures were above or below the thresholds l how long temperatures were outside the specifica...

Page 48: ...STOPPED symbol will turn off and the logger is now ready to be started again The ability to reset a logger is enabled or disabled in the Advanced Settings tab when configuring the UTRED30 WiFi via Log...

Page 49: ...y capacity of the AAA batteries if the batteries have been removed the empty symbol will be shown After a few seonds SLP will be shown on the display and the display will turn off The logger reverts t...

Page 50: ...aircraft airplane mode can be turned off using the exact same procedure l Press and hold the FN and START CLEAR STOP buttons simultaneously l Keep holding the buttons while the Airplane mode symbol o...

Page 51: ...n as detailed in EN12830 1999 Shock l Withstands shock specification as detailed in EN12830 1999 l Withstands 5 drops from 1m onto smooth concrete floor without loss of function or calibration EMC com...

Reviews: