42
Operation of LZE-V
1N1 / 3N1
5.11.3
Polypropylene (P)
(only 3N1)
Polypropylene clearing is activated by setting classes within the clearer
matrix. The length and deviation limits of the classes can be set individually
within certain limits.
Sensitivity SC / SdC:
sensitivity for short cluster (possible to remove during
piecing)
Sensitivity LC:
sensitivity for long cluster (locks cannot be removed during
piecing. They must be removed manually).
Lock condition:
repeated P-stops within the set length. In case of a lock,
check the sliver for contaminants and remove the yarn from the package.
The sensitivity can be set from 1 to 9. Setting 1 is the most sensitive. Choose
9 if you do not want to use the polypropylene cluster.