Operation
28
www.loepfe.com
WeftMaster CUT-iT Dornier
4.3.2
Resetting program settings and system parameters to standard values
Only have this carried out by qualified personnel!
Activating
when changing settings interrupts the process and Setting mode is
exited without saving the changes.
Resetting program settings of selected program
This function overwrites all current program settings with the standard values and must
be set again!
ü
The weaving machine is idle.
ü
WeftMaster CUT-iT Dornier is in
«Standby mode»
1.
Press for 3 seconds.
ð
Display:
«Default: P:X»
Standard values of selected program.
2.
Press to overwrite the program values of the selected program with standard values.
ð
The settings of the corresponding program are reset to standard values.
Resetting all program and system settings
This function overwrites all current program and system parameters with the standard
values and must be set again!
This setting can only be initialized during the startup phase!
ü
Device connected to 24 V DC-SELV supply.
1.
Press.
ð
Startup phase runs.
2.
Keep pressed during the startup phase.
ð
Display:
«Default: All»
Standard values of all settings