13
1.
Reservoir Pressure Disable/Enable
:
‘Enable’ pressurizes the reservoir and ‘Disable’
de-pressurizes the reservoir
2.
CH1 Working Status
: Four state indicators
, ‘Ready’ means system is awaiting a start
signal, ‘Stop’
means the system disables the output of each channel
, ‘Dispensing’ means
channel 1 is activated to dispense adhesive in preselected Timer/Continue mode,
‘
Alarm
’
means the system has an error for example product bottle empty, reservoir pressure out
of range etc.
3.
CH1 Mode Selection
:
Continue/Auto Timer operating mode selection
4.
Temperature
-Displays temperature value at the reservoir housing
5.
Pre. SV (Bar)
: Displays reservoir set pressure
6.
To Main page
–
Page navigation
7.
Low Level Status
: Full/Empty is displayed to provide a warning when the adhesive bottle
is becoming Empty
8.
To Parameter Setting page
–
Page navigation
9.
To Communication Setting page
–
Page navigation
10.
To Warning Message page
–
Page navigation
11.
Pre. PV (Bar)
: Displays actual pressure within the reservoir
12.
Humidity
–
Displays humidity value at the reservoir housing
13.
CH2 Mode Selection
: Continue/Auto Timer operating mode selection
14.
CH2 Working Status
:
Four state indicators, ‘Ready’ means system is awaiting a start
signal, ‘Stop’ means the
system disables
the output of each channel, ‘Dispensing’ means
channel 1 is activated to dispense
adhesive in preselected Timer/Continue mode, ‘Alarm’
means the system has an error for example product bottle empty, reservoir pressure out
of range etc.
15.
CH2 Manual Mode
: Manually start a dispensing sequence for channel 2 dispense valve
in preselected operating mode. The dispensing time in time mode corresponds to the set
value of channel 2. In continue mode, the product is dispensed when press the button,
the button will turn green at the same time. Press the button again to stop dispense, and
the button goes grey.
16.
CH2 Purge
: Enables purge of channel 2 dispense valve
17.
CH1 Manual Mode
: Manually start a dispensing sequence for channel 1 dispense valve
in preselected operating mode. The dispensing time in time mode corresponds to the set
value of channel 1. In continue mode, the product is dispensed when press the button,
the button will turn green at the same time. Press the button again to stop dispense, and
the button goes grey.
Summary of Contents for PULSE EQ RC50
Page 1: ...1 PULSE EQ RC50 Integrated Dispenser IDH 2814024 Operating Manual ...
Page 34: ...34 XS9 PLC Interface ...
Page 35: ...35 ...
Page 38: ...38 ...
Page 39: ...39 ...
Page 40: ...40 ...