Maintenance & Operational Tips
Use Loctite
®
Universal Power Supply 902520 only.
Always disconnect the power supply before servicing the unit.
If using to dispense from syringes without pistons,
optional In-Line Filter 984650 should be installed with the
Air Line Adapter to prevent fluids from entering the unit
Use 5 micron Filter –Regulator –Loctite 985397 or
equivalent for inlet air supply
The dispenser is designed and built to be relatively
maintenance free. To assure trouble free operation, the
following recommendations should be followed:
1.
Make certain air supply is clean and dry.
2.
When not in use turn vacuum off or disconnect air supply
to unit. Failure to do so could result in adhesive being
pulled back into the unit and rendering it non-functional.
3.
Avoid turning barrels upside down or laying barrel so
that material may run through airline to internal
components.
4.
Avoid connecting air supply exceeding 100 psi (6.9 bars)
5.
Use only Amyl Alcohol to clean outside surface of the
main housing.
6.
Use only soft cloth to clean the LCD.
While under warranty, the unit may be
repaired only by an authorized Henkel service
representative
.
8
Accessories and Spare Parts
Universal Power Cord and Adapter 902520
Foot Switch 902521
Syringe Stand 901459
Dual Unit Stacking Lock Pin 8900574
Air line Support Mast 8900575
6mm Inlet Air Tubing (10 meters) 902523