background image

 

 

 

 

*

*

Mejsel pozidrive

1

2

1) 

FIT BATTERIES

3) 

1)  

Remove the battery closure cap using the tools supplied.

2)  

Insert batteries in the appropriate polarity as shown.

3)  

Firmly secure the battery closure cap back into position.

*Refer to the ‘Operating Instructions’ on page 3 for more information about battery use and replacement

.    

2) 

A

 

B

 

C

 

A

 

B

 

C

 

1

2

A) Slide latch into hole and mark around latch

     face plate.

B) Chisel out face plate recess to appropriate

      depth. 

C) Insert latch with angled face of bolt towards

      door jamb and fasten with the 2 screws

      provided.

    

     NOTE: 

When completed make sure holes 

     are free of any sawdust or loose material.

Ensure your door fulfils the above

minimum requirements.

backset

32 - 45

 

mm

 

door thickness

latch recess

preparation

DOOR PREPARATION

1

8816 CODE HANDLE

FITTING INSTRUCTIONS

COMPONENTS PROVIDED

 

  

SUPPLIES

TOOLS REQUIRED

 

  

Tape measure or Ruler

Pencil 

54mm 

Hole Saw 

Power Drill 

Screw Drivers

25mm 

Spade Bit

25mm Chisel

ASSA ABLOY Australia Pty Limited, 235 Huntingdale Rd, Oakleigh, VIC 3166  ABN 90 086 451 907  ©2013
The global leader in door opening solutions

4

AUTOMATIC LOCKING

AUDIO SIGNALS

8816 CODE HANDLE

OPERATING INSTRUCTIONS

SECURITY

RESETTING THE CODE MEMORY

GENERAL SAFETY PRECAUTIONS

The 8816 Code Handle is meant for use with approved batteries only. Usage of unapproved batteries or other power supply could be dangerous.

Do not install the product outdoors or in wet environments:

   o 

The product is classified according to IP 40, in the international standard IEC 60529 stating that it holds degree 4 protection against granular 

 

foreign bodies, and degree 0 in water protection.

   o 

Do not expose to moisture, liquid, or heat due to risk of short circuit

Handle Batteries with Care:

 

The Material Safety Data Sheet for lithium batteries states that the contents of the batteries 

   can cause skin and respiratory system irritation, as well as burns. Lithium batteries can 

   rupture and release both liquids and gases.

    o 

Do not disassemble or short-circuit batteries.

    o 

Do not recharge batteries.

    o 

Do not dispose of batteries in fire.

    o 

Do not allow metal objects to contact the battery terminals.

    o 

Do not mix with used or other battery types (such as alkaline with carbon zinc).

     o 

Do not over discharge batteries. 

    o 

To install or remove batteries, follow the equipment instructions.

    o 

Keep batteries away from small children. If swallowed, consult a physician 

 immediately.

    o 

Remove batteries from the device when it is not in use.

    o 

Storage of batteries:

 Store in a cool dry place before use. 

 

Do not keep batteries at relative humidity of 65% or above.

The code handle can be reset to factory settings by changing the administrator’s code. 

The lockset will require to be removed from the door. Refer to step 3 of ‘Fitting Instructions ’ on page 2 for procedure.

When reset, the settings will be:

• 

Empty user codes

• 

Audio Signal: ON

• 

Auto Locking: OFF

    A) Mark latch centreline at the required height

          on the door edge.

             *

the recommended latch height from the

           floor is between 1040 and 1100mm

.

     B) Drill a    54mm hole in the position shown,

           from 

both sides

 of the door to prevent 

           splintering.

     C) Drill the    25mm latch hole horizontally 

           to a minimum depth of 40mm.     

IMPORTANT NOTE: 

If the product does not work remove the batteries and re-insert them according to step 2 of ‘Fitting Instructions’ on page 1. 

If the product still does not work, try fitting new batteries of an approved type. 

Protect your Code Handle:

Disassembling or misuse of the Code Handle will void your warranty.

Please ensure the Code Handle is used in accordance with the 

instructions and not subjected to any liquids, including water, 

chemicals, solvents or aerosols as these will damage the unit.

The 8816 Code Handle is delivered with the audio signal enabled.

Audio Signals On or Off

1) 

Enter programming mode by pressing the lock button for 5 seconds, until the LED lights steady red.

2) 

Enter the administrator‘s code within 5 seconds. 

 

The LED lights steady green.

3) 

Press the pushbutton 2 once to turn the audio signal on/off. 

 

A low tone indicates that the signal has been turned off. A high triple-tone indicates that the signal has been turned on.

4) 

Confirm the change

 and exit the programming mode by pressing the lock button, or wait until the green LED turns off. 

The 8816 Code Handle is delivered in manual mode which can be switched to Automatic Locking mode.

WARNING!

 

In automatic locking mode, the code handle will repeatedly attempt to re-lock within 9 seconds from opening. 

If the handle is not returned to its horizontal position within this time frame, the handle will remain unlocked. 

This effect is similar to the temporary unlocking as described below.

Automatic Locking On or Off

1) 

Enter programming mode by pressing the lock button for 5 seconds, until the LED lights steady red.

2) 

Enter the administrator‘s code within 5 seconds. 

 

The LED lights steady green.

3) 

Press the push button 3 once to change the mode to/from automatic locking. 

 

A low tone indicates that Auto Locking has been turned off.  A high triple-tone indicates that Auto Locking has been turned on.

4) 

Confirm the change

 and exit programming mode by pressing the lock button, or wait until the green LED turns off.

Temporary Unlocking

1) 

Enter a correct user code and wait until the LED stops flashing.

2) 

Immediately press pushbuttons 1 and 4 at the same time.

 

The door is now unlocked until the next time the lock button is pressed or a user code is entered, 

 

after which the handle returns to automatic locking mode.

110mm min width of lock stile

for timber framed glass doors

hole preparation

latch recess preparation

 

 

 

 

+

+

-

-

SECURITY

P

A

 

C

 