LockTech AccuReader X270 Instructions Download Page 1

 

 

 

X270 (ZADI) 

 

by    

 

LockTech 

 

www.locktech.biz 

[email protected]

 

 

 

Thank you for purchasing the AccuReader 

wafer reading system by LockTech.  This system will 
allow you to read the Zadi (X270) ignition and other 
locks without the removal of the ignition or other locks. 
Following a few simple steps it takes only minutes to 
read the depths for each cut in each position for a 
complete key. 
 
 

The AccuReader works on the process of 

elimination to decipher the correct depths of the lock.  
By checking the deepest cut first you eliminate what 
the cuts are not.  Therefore it is essential to always 
read depth slide #4/3 first. 
 
 

The AccuReader key is designed to be used 

for wafer positions 4-7 on one side of the key and 
wafer positions 1-3 on the opposite side of the key.  It 
is recommended to start from the rear of the lock and 
work outward to the number 1 position. 
 

 

 

Please take the time to familiarize yourself 

with the tools and verify all pieces are accounted for 
from the list of contents below: 
 
Package Contents: 
1-AccuReader key 
1-insertion/release slide 
1-depth slide #4/3C 
1-depth slide #4/3OS 
1-depth slide #2C 
1-depth slide #2OS 
1-Tube storage container 
1-Tube Cap 
 

 
 
USING THE ACCUREADER on CENTERED 
KEYWAYS 
 

1) Always thoroughly clean the lock with a electronics 
safe cleaner to free any potentially stuck wafers. 
 
2) Use the alignment holes through the AccuReader 
key to assist in judging the distance from one wafer 

position to the next.  

CENTERED Zadi keyways have 

opposing wafers. 

 
3) Place the insertion/release slide in the slot on the 
AccuReader key.  Fully insert the AccuReader key into 
the keyway and remove the slide.  The AccuReader 
key should trap a wafer without pulling out any.  If the 
AccuReader key pulls out some before trapping a 
wafer, flip the AccuReader key over and resinsert fully 
to trap wafer #6.  It is now ready to read the #6 wafer. 
  
4) Always

 start reading with the #4/3C depth slide 

tool, and then proceed to #, if necessary. 

 Fully 

insert the depth slide into the AccuReader key.  The 
alignment mark on the depth slide will line up with the 
(

Y

Yes

 mark or it will line up with the (

N

)

 No 

mark.  

 
  

a) If the #4/3C depth slide lines up with the 

Y

 

then the depth for space #6 wafer is a 4 or 3.  If the 
depth slide lines up with a 

N

, then you must proceed to 

the #2C depth slide.  
  
 

b) If the #2C depth slide lines up with the 

Y

 

then the depth for space #6 wafer is a 2.  If the depth 
slide lines up with a 

N

, then the depth for space  #6 is a 

1. 
 
 

c) Repeat steps a & b for each even wafer 

position reading 6, 4 & 2.  Flip the AccuReader over 
and read spaces 5, 3, & 1. 
  
 

d) 

Cut all 1’s to 1’s, 2’s to 2’s and 4/3 depths to 

a 3.5.  The key should turn in the lock relatively easily, 
do not force.   Any spaces that marked should be 
moved to a 4 depth and any spaces that did not mark 
should be recut to a 3 depth. 
 
 

e) You now have recorded all the positions to 

make a complete key. 
 
 
 
 
 

USING THE ACCUREADER on OFFSET KEYWAYS 
 

1) Always thoroughly clean the lock with a electronics 
safe cleaner to free any potentially stuck wafers. 
 
2) Use the alignment holes through the AccuReader 
key to assist in judging the distance from one wafer 
position to the next.  

OFFSET  Zadi keyways have 

wafers only on one side. 

 
3) Place the insertion/release slide in the slot on the 
AccuReader key.  Fully insert the AccuReader key into 
the keyway and remove the slide.  The AccuReader 
key should trap a wafer without pulling out.  If the 
AccuReader key pulls out without trapping a wafer, flip 
the AccuReader key over and resinsert fully to trap 
wafer #6.  It is now ready to read the #6 wafer. 
  