LockTech AccuReader KM12 Quick Start Manual Download Page 1

 

 

 

KM12 

 

by    

 

 

 

www.accureader.com 

[email protected]

 

 

 

Thank you for purchasing the AccuReader by 

LockTech wafer reading system.  This system will 
allow you to read the KM12 ignition completely and 
accurately without the removal of the ignition. 
Following a few simple steps it takes only minutes to 
read the depths for each cut in each position for a 
complete key. 
 
 

The AccuReader works on the process of 

elimination to decipher the correct depths of the lock.  
By checking the deepest cut first you eliminate what 
the cuts are not.  Therefore it is essential to always 
read depth slide #4 first. 
 
 

The AccuReader  key is designed to be used 

for wafer positions 4-7 on one side of the key and 
wafer positions 1-3 on the opposite side of the key.  All 
seven positions can be read from the 4-7 side of the 
key, however it is recommended to flip the key over 
and use the 1-3 side.  This allows for reading the 1-3 
wafer positions with a fully or almost fully inserted key, 
increasing the accuracy. 
 

 

 

Please take the time to familiarize yourself 

with the tools and verify all pieces are accounted for 
from the list of contents below: 
 
Package Contents: 
1-Accu-Reader key 
1-insertion/release slide 
1-depth slide #4 
1-depth slide #3 
1-depth slide #2 
1-Tube storage container 
1-Tube Cap 
 

 
 
 
 
 
 
 

 
USING THE ACCU-READER 
 

1) Always thoroughly clean the lock with a electronics 
safe cleaner to free any potentially stuck wafers. 
 
2) Use the alignment holes through the AccuReader 
key to assist in judging the distance from one wafer 
position to the next. 
 
3) Place the insertion/release slide in the slot on the 
AccuReader key on the #4-7 side.  Fully insert the 
AccuReader key into the keyway and remove the 
slide.  The AccuReader key is now ready to read the 
#7 wafer.  

(Note:  If the 

AccuReader 

trapped a wafer 

shortly after inserting it into the keyway, use the 
release slide on the opposite side of the key to 
release the 

AccuReader

.  This happens when 

wafers fall into the trap slot for the 1-3 side, since 
these locks have wafers only on one side.  Flip the 

AccuReader 

over and restart step 2). 

 
4) Always

 start reading with the #4 depth slide tool, 

then proceed to #3, then #2 if necessary. 

 Fully 

insert the depth slide into the AccuReader key.  The 
alignment mark on the depth slide will line up with the 
(

Y

Yes

 mark or it will line up with the (

N

)

 No 

mark.  

 
  

a) If the #4 depth slide lines up with the 

Y

 then 

the depth for the #7 wafer is a 4.  If the depth slide 
lines up with a 

N

, then you must proceed to the #3 

depth slide.  
  
 

b) If the #3 depth slide lines up with the 

Y

 then 

the depth for the #7 wafer is a 3.  If the depth slide 
lines up with a 

N

, then you must proceed to the #2 

depth slide. 
 
 

c) If the #2 depth slide lines up with the 

Y

 then 

the depth for the #7 wafer is a 2.  If the depth slide 
lines up with a 

N

, then the depth for wafer #7 is a 1. 

 
 

d) Repeat steps a through c for each wafer 

position until you have recorded the depth for wafer 
position 4. 
 
 

e) Using the insertion/release slide remove 

the AccuReader key from the keyway and flip it over.  
Insert the insertion/removal slide on the #1-3 side of 
the AccuReader and fully insert the AccuReader key 
back into the keyway.  You are now ready to read 
wafer position #3. 
 
 

f) Repeat steps a through c for each wafer 

position until you have recorded the depth for wafer 
position #1. 
 
 

g) You now have recorded all the positions to 

 make a complete key. 
 
 

 

Reviews: