background image

DU40•20 Technical Manual EN 150624

© 2015 www.Lock4Safe.com

Page 1 of 4

DUET

DU4020 / DU4050
Technical Description/Installation Instruction

Characteristics

The Duet © combines an electronic safe lock and a mechanical Combination lock in one housing. The
operator  uses  the  advantages  of  both  Systems.  The  lock  has  the  standard  mounting  dimensions
(66,5x41mm) and can be mounted in all 4 mounting positions. (RH, LH, VU, VD)

The lock can be mounted in typical security containers.
Dimension:  85  mm  x  61  mm  x  37 mm. NOTE: Because  of  the  electronics,  the  housing  is  5-8  mm
thicker than a normal combination lock.
Lock bolt: 25mm x 8mm with 2 holes (ready to tap M4 if required). The throw is 8mm. Max bolt force
10N.

The  lock  may  be  mounted  with  the “DuetInput” DIxxxx as  shown in  this  instruction or  with  any
approved entry  unit  and separate dial. The  lock  is  driven  by  a  4,7  mm  (3/16  inch)  square spindle,  a
spline key is not required. The distance between change and opening index is 8 ¼ numbers.

The  construction  of  the  security  container  needs  to  include  protection  against  destructive  force  from
outside and should not give access to security relevant parts of the lock even with open door.

Installation dimensions

The diameter of the hole for cable and spindle should be minimal 8mm, maximal 12mm. Deburr the
spindle hole to avoid damage to the cable.

The cable does not move or wear when using the lock. However, the installer needs to take care that
the cable is not touching moving parts. For new constructions and if possible, it is advised to create a
separate hole for the cable. If spindle and cable share the same hole, use the plastic tube over the
spindle only to separate it from the cable.

Summary of Contents for DUET DU4020

Page 1: ... DIxxxx as shown in this instruction or with any approved entry unit and separate dial The lock is driven by a 4 7 mm 3 16 inch square spindle a spline key is not required The distance between change and opening index is 8 numbers The construction of the security container needs to include protection against destructive force from outside and should not give access to security relevant parts of th...

Page 2: ...be needed to accommodate a relocker Use Loctite to secure the screws approximately 3 5 Nm torque Plug the four input s prong connector into the ENT slot of the lock Thereafter press the nose of the plug lightly behind the metal housing so that it does not come loose during use 5 Cut the shaft for the mechanical dial and deburr both ends Length 41 mm D door thickness Insert the cut shaft into the s...

Page 3: ...er the spindle only to separate it from the cable 12 Remove the spacer With the lock in OPEN position bolt retracted hold the dial in a way that approximately 93 is lined up with the dial s opening mark and push it with light pressure into the lock The dial and shaft cannot be pulled back out as they are held by a starlock washer 13 Place the small plastic plug into the shaft hole at the rear of t...

Page 4: ...dial if a number is passed start over at the beginning After the new Code is completely entered turn change key LEFT and remove it The new Code is installed Try the new code several times using Opening Index before closing the door What if accidentally the cam got moved before installation As long as the code has not been changed with the change key the lock can be prepared for mounting following ...

Reviews: