79
Free Mode Profile Message (Version 1) - Profile Attributes
Field
Type
Description
viewIndex
k64s
View index (0 left, 1 right)
frameIndex
k64s
Sequence index
timestamp
k64s
Capture time (microseconds)
encoder
k64s
Capture position (encoder pulses)
encoderIndex
k64s
Encoder pulse index
IOState
k64s
Digital I/O states (bits 0 to 3 are states of
inputs 0 to 3)
7.4.2
Calibration Mode
In
Calibration
mode, the server assumes that the first scanned object is the system
calibration bar. All objects after the first scanned object are ignored. Calibration
algorithms are applied to the data and a series of messages are sent to the client.
One Detection Profile, Detection Vision, and/or Detection Tracheid message is sent for
each of the Top and Bottom groups (if present). Collectively, these messages represent
a scan of the calibration bar with the calibration results applied to the data. After these
detection messages, a
Calibration Completed
message is sent.
Calibration information is stored in a file named "Calibration.xml" that can be accessed
using the FireSync Host Protocol
Read File
and
Write File
commands. The format of this
file is described in Section 7.3.3 Calibration Output.
Note:
In multi-server installations, the x and y reference values included in the
Calibration
Completed
message
can
be
used
to
determine
appropriate
Calibration/XAdjustment
and
Calibration/YAdjustment
values for Settings.xml files.
FireSync Client averages the x- or y-reference values from each server, then subtracts
the average from each individual x- or y-reference value and writes the resulting values
into each
server’s Settings.xml file.
Calibration Completed Message (Version 3)
Field
Type
Description
messageSize
k64s
Total size of message (bytes)
messageId
k64s
Type of message (14)
reserved[2]
k64s
Reserved for internal use
deviceId
k64s
Server serial number
result
k64s
Calibration status:
Success (1)
Warning (1000)
Error (2000)
Data Collection Error (2001)
Data Processing Error (2002)
Data Reply Error (2003)
yReference
k64s
Calibration y-reference for this server (mils).
xReference
k64s
Calibration x-reference for this server (mils).
reserved[2]
k64s
Reserved for internal use
issueCount
k64s
Count of issues
Summary of Contents for chroma+scan 3155
Page 1: ...chroma scan 3x00 Document Version 4 11 12 30...
Page 14: ...14 3 1 1 Sensors chroma scan 3155 chroma scan 3250 chroma scan 3350...
Page 31: ...31 5 5 Dimensions and Mounting 5 5 1 chroma scan 3155 Sensor Dimensions...
Page 32: ...32 5 5 2 chroma scan 3250 Sensor Dimensions...
Page 33: ...33 5 5 3 chroma scan 3350 Sensor Dimensions...