Review the guidance in this chapter if you are experiencing difficulty with a GoMax unit.
Mechanical/Environmental
The unit is warm.
l
It is normal for a GoMax unit to be warm when powered on.
Connection
When attempting to connect to the GoMax unit with a web browser, the unit is not found (page does
not load).
l
Verify that the GoMax unit is powered on and connected to the client computer network. The power indicator
LED should illuminate when it is powered.
l
Check that the client computer's network settings are properly configured.
l
Use IP scanning software to verify the IP address of the GoMax unit. For more information, see
Performance
The CPU level is near 100%.
l
Consider reducing the speed. If you are using a time or encoder trigger source, consider reducing the speed.
If you are using an external input or software trigger, consider reducing the rate at which you apply triggers.
l
Consider reducing the resolution of the sensors in the system.
l
Review the measurements that you have programmed and eliminate any unnecessary measurements.