LXC63X0/LXC51X0
Generator controller user manual
Dongguan Tuancheng Automation Equipment Co.,LTD.
LXC63X0/LXC51X0
Generator controller user manual.
Dongguan Tuancheng Automation Equipment Co.,LTD.
�
:
T:+86 0769-23162896
�
:
F:+86 0769-23166296
�
::::
www.lixise.com
Page
16 of 36
�
:
T:+86 0769-23162896
�
:
F:+86 0769-23166296
�
::::
www.lixise.com
Page
16 of 36
5.2.
5.2.
5.2.
5.2. S
S
S
Shutdown
hutdown
hutdown
hutdown A
A
A
Alarm
larm
larm
larm
When controller detects shutdown alarm, it will send signal to stop the generator to load out, and the
display alarm type.
Shutdown alarms as following:
No
Warning types
Description
1
Emergency Stop
When controller detects emergency stop signal, it will send a stop alarm
signal and it will be displayed in LCD.
2
High Temperature
When controller detected the temperature of water/cylinder is higher than
preset, it will send a stop alarm signal and it will be displayed in LCD.
3
Low Oil Pressure
When controller detected oil pressure is lower than the preset, it will send
a stop alarm signal and it will be displayed in LCD.
4
Over Speed
When controller detected genset speed is over the preset, it will send a
stop alarm signal and it will be displayed in LCD.
5
Under Speed
When controller detected genset speed is under the preset, it will send a
stop alarm signal and it will be displayed in LCD.
6
Loss Of Speed
Signal
When controller detected genset speed is 0 ,it will send a stop alarm
signal and it will be displayed in LCD.
7
Over Frequency
When controller detected genset frequency is over the preset, it will send
a stop alarm signal and it will be displayed in LCD.
8
Under Frequency
When controller detected genset frequency is under the preset, it will
send a stop alarm signal and it will be displayed in LCD.
9
Over Voltage
When controller detected genset voltage is over the preset, it will send a
stop alarm signal and it will be displayed in LCD.
10
Under Voltage
When controller detected genset voltage is under the preset, it will send a
stop alarm signal and it will be displayed in LCD.
11
Over Current
When controller detected genset current is over the preset and delay is
not 0, it will send a stop alarm signal and it will be displayed in LCD.
12
Fail To Start
During the start attempt times, if genset start failed, it will send a stop
alarm signal and it will be displayed in LCD.
13
Oil Pressure
Sensor Open
When oil pressure sensor opens circuit and the input is active, controller
will send a stop alarm signal and it will be displayed in LCD.
14
Input Port 1-6
When controller detected the input port 1-6 external warning is active,
controller will send shutdown alarm signal and it will be displayed in LCD.
15
D+ Open shutdown
Generator starting on the D+ connected to detect if an alarm when open.
Note:
Note:
Note:
Note:
the
the
the
the input
input
input
input port
port
port
port shutdown
shutdown
shutdown
shutdown alarm
alarm
alarm
alarm types,
types,
types,
types, must
must
must
must be
be
be
be user
user
user
user configuration,
configuration,
configuration,
configuration, to
to
to
to be
be
be
be effective.
effective.
effective.
effective.
5.3.
5.3.
5.3.
5.3. Trip
Trip
Trip
Trip Alarm
Alarm
Alarm
Alarm
When controller detects shutdown alarm signal, it will shutdown generator quickly and stop after high
speed cooling.
Trips shutdown alarm as following:
No
Warning type
Detection range
Description
1
Over Current
Remain valid
When controller detects the value is higher than the set
value, and the action select "trip and shutdown", it will send
a trip alarm signal and it will be displayed in LCD.
2
Input port 1-6
The user setting
range
When digital input port 1-6 is set as "trip and shutdown",
and the action is active, it will send a trip alarm signal and it
will be displayed in LCD.
Note:
Note:
Note:
Note:
the
the
the
the input
input
input
input port
port
port
port trip
trip
trip
trip alarm
alarm
alarm
alarm types,
types,
types,
types, must
must
must
must be
be
be
be user
user
user
user configuration,
configuration,
configuration,
configuration, to
to
to
to be
be
be
be effective.
effective.
effective.
effective.